Kansas City, KS Residential HVAC & Plumbing Services
LBA Heating, Cooling, Plumbing & Electrical was started by people just like you who want and insist on high quality and reliable service. In Kansas City, KS and throughout the Kansas City area, we treat each family and home as if it were our own. That includes rising to the challenge of being a Hero any time the need calls for extraordinary measures.
From routine maintenance to 24/7 emergency repairs, LBA Heating, Cooling, Plumbing & Electrical has you covered for all your home plumbing, heating, and air conditioning needs. The same goes for new and replacement system installations. Read our reviews and find out why your neighbors consider us to be their nearby heating and air company and local plumber in Kansas City, KS.
Recent Jobs and Reviews in Kansas City, KS
Kansas City, KS at a glance
LBA Air Conditioning, Heating & Plumbing has completed 25 jobs in Kansas City, KS in January 2025.
The most recent job was on January 23, 2025.
LBA Air Conditioning, Heating & Plumbing has completed 131 jobs in Kansas City, KS in the last 12 months. The first job there was in December 2014.
Our Local Reviews by City
- Adrian, MO (2)
- Avondale, MO (1)
- Basehor, KS (24)
- Bates City, MO (1)
- Belton, MO (33)
- Blue Springs, MO (72)
- Bonner Springs, KS (30)
- Buckner, MO (1)
- Bucyrus, KS (6)
- Columbia, MO (1)
- De Soto, KS (25)
- Dearborn, MO (1)
- Edwardsville, KS (14)
- Eudora, KS (9)
- Fairway, KS (93)
- Freeman, MO (1)
- Gardner, KS (14)
- Gladstone, MO (65)
- Grain Valley, MO (58)
- Grandview, MO (75)
- Greenwood, MO (3)
- Holt, MO (3)
- Houston Lake, MO (7)
- Independence, MO (184)
- Kansas City, KS (427)
- Kansas City, MO (2902)
- Kearney, MO (3)
- Lake Lotawana, MO (4)
- Lake Quivira, KS (22)
- Lake Waukomis, MO (4)
- Lake Winnebago, MO (1)
- Lansing, KS (2)
- Lawrence, KS (19)
- Leavenworth, KS (8)
- Leawood, KS (429)
- Lee's Summit, MO (164)
- Lenexa, KS (608)
- Liberty, MO (116)
- Lone Jack, MO (1)
- Louisburg, KS (5)
- Merriam, KS (21)
- Mission, KS (204)
- Mission Hills, KS (78)
- North Kansas City, MO (10)
- Northmoor, MO (1)
- Oak Grove, MO (13)
- Odessa, MO (1)
- Olathe, KS (632)
- Ottawa, KS (1)
- Overland Park, KS (1458)
- Paola, KS (1)
- Parkville, MO (191)
- Peculiar, MO (1)
- Platte City, MO (13)
- Pleasant Hill, MO (1)
- Pleasant Valley, MO (4)
- Prairie Village, KS (527)
- Prairie Village New, KS (2)
- Raymore, MO (27)
- Raytown, MO (84)
- Riverside, MO (18)
- Roeland Park, KS (189)
- Shawnee, KS (1045)
- Shawnee Mission, KS (2)
- Smithville, MO (1)
- Spring Hill, KS (13)
- Stilwell, KS (66)
- Sugar Creek, MO (7)
- Weatherby Lake, MO (31)
- Wellsville, KS (1)
- Westwood, KS (30)
- Westwood Hills, KS (18)
Job Locations and Reviews
Came out here for a furnace tuneup upon arrival tested static static was passing on the unit checked everything else in the unit filter was clean. I cleaned out the flame sensor for them. Make sure that all amps within the unit were under the manufacture specifications. Everything seem to be good here exchanger look good no carbon monoxide readings. I did notice that the blower wheel itself was extremely dirty, so I let customer know about that supervisor is out taking a look at damaged water heater.
L
L
L
L
Went for a furnace inspection today. Did a static pressure test, it failed. Filter got changed. Did a carbon monoxide and gas leak test, no leaks. Combustion analysis test passed. Inducer motor amperage passed. Gas pressure and pressure switch passed. Flame sensor got cleaned. Exhaust flu is in good condition. Temperature split between the supply and return duct passed. Blower motor amperage passed and blower wheel is clean. Thank you for choosing LBA services!
It was 52 degree in the break room when I arrived. Some vent are blowing heat and half was not. Found a second thermostat in the room to the east of break room that was not on. Turned system on and all vents now have heat and when I left it was 63 in break area.
1-21-25 Spoke to Mother Amy upon arrival. The area that’s not heating is on the first floor south. The forced air furnace blower motor is out York model # TG9S080B12MP11B Serial # W1D7606460 Ordered and picked up a new blower motor and run capacitor. Installed new blower motor and run capacitor tested furnace for proper operation. Cycled it from thermostat. It’s working at this time. While on site, I checked the chemical feed for the boiler system. Had a leaking fitting yesterday is not leaking and working properly.
Arrived to remedy a leaking exhaust vent for the furnace. Determined where the water is leaking, and built a parts list. Went to go get the proper pieces of pvc. Returned and cut out the leaking section of the vent. Remade a section to fit in place. Dry fit it to ensure it would fit. Cleaned up all the pvc shavings inside and outside of the furnace. Glued the sections of pvc vent pipe together and secured it in place. Fired suystem and verified operation of all components. Found that the humidifier is not working. Installed a transformer to power the humidifier and made sure it would work. Found a damaged wire, and remade the connection. Verified operation of the humidifier to ensure it will operate without leaking. Furnace is functioning properly at this time.
N
N
N
N
Arrived to replace a failing furnace control board. System was intermittently not heating. Removed the old control board and traced out each of the wires and landed them on the proper terminals on the new board. Wired in an additional ground and verified there is a common wire to the thermostat. All of this is in an attempt to keep the control board from having a similar failure in 6 months. Fired system up and verified operation. Furnace is operating properly at this time.
1-20-25 Room 312 on the 3rd floor around the steam radiator there is condensation on the ground, and the wood floor is stained. I found the supply steam dielectric union is badly rotted and leaking. Ordered and picked up a new half inch dielectric union. Installed the new union and found the return line after the steam trap which I tested is clogged. This radiator and the one to the north will not work. However, the units on the second floor are working fine. There is a clogged line on the return between the second and third floor right now. At this time I’m not gonna do a repairs per Mother Amy
Upon arrival I began the furnace tune up. First, I ran a static pressure test. Your system is rated for a maximum static pressure of .5 and the test showed the system at .4 which is at 80% of the maximum which is exactly what the manufacturer wants it to be at. Next, I checked the running amps on the inducer and blower motor. The inducer was amping a little high and the blower motor was as well. I found out the reason they are amping higher than normal is because the blower wheel is clogged up with puppy hair and debris which makes it harder for the wheel to spin. This is another reason why the whole home isn’t warming like it should because the blower wheel isn’t spinning fast enough like it should. I took a temperature split on the unit and it was at 139 degrees - 72 degrees = 67 degree temp rise. The manufacturer specs says it should be between 40 & 70 degrees so we are right at the top of the temp rise range. Once the blower wheel is cleaned, it will help with heating the home much
Found hole in hx. Customer has home warranty
Arrived to remedy an inoperable furnace. Upon inspection of the system found it displaying an idle code and would reset the board, despite having a call for heat present. Verified all voltage is in the proper places. Determined there is an internal failure in the control board. Without a supply house open ant this time am unable to perform this repair. After cycling power and cycling through the menu options on the control board the system is responding to commands from the thermostat. Showed homeowner how to reset the system and hopefully get it running if it stops heating again this evening. Will return Monday morning with correct parts to perform repairs.
.
Arrived to do a performance maintenance. Verified operation of the heat pump and temperature split. Switched system over to emergency heat for the gas furnace. Set up for combustion analysis temperature split and static pressure tests. Found that the system is operating with higher static pressure than the manufacturer would approve. Verified operation of all mechanical and electronic components of the furnace. Checked blower for cleanliness and to see if there is any play in the bearings. Found that the fan for both heating and cooling is coated in dust. Checked systems heat exchanger to ensure proper venting of flue gas. Verified operation of the humidifier. Found manual dampers in the ductwork restricting airflow. Spoke with homeowner about the system. Furnace is operational at this time.
Water Heater Replacement: A failing water heater with frequent breakdowns was replaced with an energy-efficient model. The upgrade improved reliability, reduced energy consumption, and provided a steady hot water supply for the homeowner.
Customer did not answer once again. He has voicemails and text messsages but have never replied
Installed New Full System, Water Heater w/ Expansion Tank and AprilAire 600 Humidifier. Furnace Model FR801T1005A21UHSNA, AC Unit Model FRA14AZ36AJ1NAM, Evap Coil Model FTCFZ3621STANMC 2 Year Labor Warranty 10 Year Parts Warranty Limited Lifetime Heat Exchanger Warranty Water Heater Warranty 2 Year Labor 6 Year Tank & Pars
Estimates
Preformed plumbing inspection showed findings to customer turned over to supervisor