Home Air Conditioning, Heating & Plumbing Services in Grandview, MO

From routine maintenance to 24/7 emergency repairs, LBA has you covered for all your home plumbing, heating, and air conditioning needs.  The same goes for new and replacement system installation.

In Grandview and throughout the Kansas City area, we treat each family and home as if it were our own.  That includes rising to the challenge of being a Hero any time the need calls for extraordinary measures.   

LBA was started by people just like you who want and insist on high quality and reliable service.  We continue to abide by those principles.

Grandview MO AC Heating and Plumbing

Local Reviews
for Grandview, MO

LBA Air Conditioning Heating and Plumbing Rated 4.9 out of 5 stars based on 22 customer reviews


Map of Grandview, MO

Good service




Review of LBA Air Conditioning Heating and Plumbing

Very timely and honest


Map of Grandview, MO

Courteous And professional




Review of LBA Air Conditioning Heating and Plumbing

Jerry was Courteous knowledgeable and professional.


Map of Grandview, MO

Great




Review of LBA Air Conditioning Heating and Plumbing

Austin was the technician and he did great job.


Map of Grandview, MO

Good!




Review of LBA Air Conditioning Heating and Plumbing


Map of Grandview, MO

Efficient, professional, friendly.




Review of LBA Air Conditioning Heating and Plumbing


Map of Grandview, MO

Technicians are very professional, always willing to share information on repair needed and options availalble.




Review of LBA Air Conditioning Heating and Plumbing

You will not find a better heating and cooling company.


Map of Grandview, MO

Very pleased 😀




Review of LBA Air Conditioning Heating and Plumbing

Phil was vey polite and informative. Discussed repair vs replace .


Map of Grandview, MO

Good service, Technicians are great




Review of LBA Air Conditioning Heating and Plumbing


Map of Grandview, MO

Facilities Manager




Review of LBA Air Conditioning Heating and Plumbing


Map of Grandview, MO

Great service and professional




Review of LBA Air Conditioning Heating and Plumbing

Angelina is always professional and explains everything she is doing and will answer any and all questions I have.


Great service




Review of LBA Air Conditioning Heating and Plumbing

Angelina explained everything in detail and returned immediately when the first repair didn't work.


Great Service




Review of LBA Air Conditioning Heating and Plumbing


Helpful




Review of LBA Air Conditioning Heating and Plumbing

Very helpful, pleasant to work with. Angelena was very proficient and explained our plumbing system thoroughly. I feel equipped and will continue to use LBA/recommend in the future.


Great Service and Hunter was very professional and nice




Review of LBA Air Conditioning Heating and Plumbing


Great Service




Review of LBA Air Conditioning Heating and Plumbing


Doug A.

Doug A.

Upon arrival customer complained of sewer smell coming from kitchen sink, when she runs dishwasher. She was concerned that her sewer was backing up and causing this to happen, diagnosed old cast iron in unfinished mechanical room and a dry floor drain to be more the issue. Leaving quote for repair.

Near Manchester Ave, Grandview, MO 64030
Nathaniel R.

Nathaniel R.

Kitchen drain was backing up so I cabled the line and flushed gallons of water down it. Everything tested good.

Near E 137th St, Grandview, MO 64030
Matthew R.

Matthew R.

Upon arrival found out the combustion motor was no longer working. Therefore not allowing the furnace to turn on. Called customer, customer approved gold package. Completely changed out and recalibrated combustion motor and pressure switches. Completely set the furnace to manufacture specification. Cleaned all safety switches and recalibrated. Cleaned out blower cabinet space and air movement motor. This system is now working to manufacture specification

Near Ballantrae Dr, Grandview, MO 64030
Jerry B.

Jerry B.

I preformed a safety inspection on the heat pump the heat pump is working properly at this time. The customer states that sometimes the system will continue to run even after the thermostat has been satisfied or even manually turned off, causing the house to get very hot. The system has cycled off three times in a row properly for me. I suggest changing the thermostat.

Near E 125th Terrace, Grandview, MO 64030
Matthew R.

Matthew R.

Found insulation on the line set out into the evaporator to have a 1ft section that was separated and foam taped together. The tape had come unglued leaving a open crack just before the evaporator causing condensation to pool in he insulation. The condensation eventually poured out through the ceiling. I rapped both ends of the refrigeration lines with foam tape to create a air tight seal. This should prevent future condensation issues.

Near Cartwright Ave, Grandview, MO 64030
Nathaniel R.

Nathaniel R.

Cabled main line for the $88 special and the customer didn’t want a camera. Can’t warranty work that was done today.

Near Lowell Ave, Grandview, MO 64030
Nathaniel R.

Nathaniel R.

Upon arrival the customers kitchen faucet had no water pressure at all. I took the head off and showed her the water build up in the head. I cleaned it out and put the head back on. The pressure was better but wasn’t great. I recommend that the faucet should be replaced and quoted her on a customer supplied faucet. Collecting trip charge.

Near E 126th St, Grandview, MO 64030
Nick L.

Nick L.

Checked all operations in the heating mode cleaned out housing of furnace and performed a combustion analysis. Replaced furnace filter with lba supplied filter. System is heating properly at this time.

Near St Andrews Dr, Grandview, MO 64030
Nick S.

Nick S.

Checked all operations in the heating mode. Performed a combustion analysis as well as checking carbon and oxygen levels. Cleaned furnace wheel as well as furnace itself, furnace filter was changed at this time and system is operating within factory specifications at this time. Customer stated that they did not receive their air conditioner tune up which was done at this time. Checked all operations in the cooling mode. Checked all electrical components on the outdoor unit. Washed out the outdoor unit. System is operating within factory specifications at this time. Very nice meeting and talking to you.

Near Overhill Rd, Grandview, MO 64030
Rick B.

Rick B.

Checked the Rasond mini split for the IT room for no cool. Found the condenser fan not running in the condenser. Found the power supply from the main control board in the indoor head not supplying power to the condenser fan motor. Bypassed the relay on the board for continuous operation till a board can be located for repairs. Also replaced the weak capacitor for the fan motor.

Near Botts Rd, Grandview, MO 64030
Phil N.

Phil N.

Installed customer supplied kitchen faucet. 30 day warranty.

Near Valley Brook Dr, Grandview, MO 64030
Rick B.

Rick B.

Checked the Aaon unit for the building air make up for high humidity complaints in the building. Found the unit cooling normal. Ajusted the settings in the controller for a lower evaporator temp, lower outdoor dew point and closed the outdoor air damper to 50% from 100%. The unit is controlled by supply air temp, outdoor air temp and outdoor humidity. Explained the repairs to Karyn F.

Near Cartwright Ave, Grandview, MO 64030
Mason F.

Mason F.

Installed 5 ton RTU, tested operation of all functions. 208 volts

Near Cartwright Ave, Grandview, MO 64030
Cody A.

Cody A.

Performed maintenance on all units found operating well at this time.

Near Botts Rd, Grandview, MO 64030
Jerry B.

Jerry B.

I preformed maintenance on the mini split system. Brad just cleaned the filters, I advised him to make sure the filters were dry before he put the back in. I washed out the outdoor unit. Everything is operating within factory specifications.

Near Sycamore Ave, Grandview, MO 64030
Rick B.

Rick B.

Checked the 13 ton air make up Aaon for humidity issues in the building. Found the blower running with no cooling. Found the humidity sensor connection loose at the control board in the unit. Secured the connection. Found the unit cooling normal after repairs. Also checked the setup and configuration in the remote controller. Ajusted the setpoints for proper operation. Also took info on replacing the Northeast Trane Rtu and sent the details to Zach for quoting.

Near Cartwright Ave, Grandview, MO 64030
Phil N.

Phil N.

Patty had water coming out of ceiling from upstairs bathroom. On further inspection.toilet bolts on old toilet leaking. Discussed options Patty chose band aid toilet replacement. Replaced toilet and checked for leaks no leaks found 30 day warranty.

Near Lowell Ave, Grandview, MO 64030
Jerry B.

Jerry B.

I came out to start up and test the new air conditioning system we installed. Readings 236 volts Discharge gauge 97 Discharge line 90 Subcooling 8 Suction gauge 54 Suction line 65 Super heat 11

Near 7 St, Grandview, MO 64030
Aaron R.

Aaron R.

After inspecting the furnace for the noise we found that the blower motor bearings have failed causing the wheel to be out of balance and creating a lot of noise. We presented options to the customer for repairs but the customer declined at this time stating that she would be using her home warranty.

Near Manchester Ave, Grandview, MO 64030
Gary P.

Gary P.

Check lobby unit found no cooling. Found unit off on error code A3 (open condensate switch). Removed covers, fans grauds, and drain plugs and did not find any standing water in a pan. The float switch and condensate pump are not accessible without disconnecting the unit from the refrigerant circuit. If the problem continues the unit float switch should be replaced. Check unit on 2floor for condensate leaks. Found condensate drains sweating. Check aaon unit for proper operation. Found aaon unit working properly at this time.

Near Cartwright Ave, Grandview, MO 64030
Rick B.

Rick B.

Checked the North IT room Daikin mini split for no cool. Found the unit low on refrigerant. Leak searched the unit and found the leak at the condenser low side flare connection. Repaired the leak. Removed and weighted the existing R410a. Added back the removed refrigerant and added new to the correct charge. Started the system and verified operation. Also verified the operation of the South Daikin mini split for the IT room. Checked the commons entry area Daikin cassette for A3 error code of condensate drain back up. Cleaned the condensate line and the pump-float sump. Started the unit and verified operation. Repairs were approved by Karyn Forsythe

Near Cartwright Ave, Grandview, MO 64030
Jerry B.

Jerry B.

Preforming a p3 safety and maintenance inspection I found the air conditioner to be operating within factory specifications.

Near E 138th St, Grandview, MO 64030
Ian B.

Ian B.

Found vrf head plastic shroud broken at and near a previous repair. I added some screws and strap to secure shroud back to the unit. This repair while not cosmetically perfect, will allow the unit to safely stay in operation.

Near Cartwright Ave, Grandview, MO 64030
Derek B.

Derek B.

We gathered information to prepare a replacement proposal for the pump house exhaust fan. No charge for this call.

Near Botts Rd, Grandview, MO 64030
Eli M.

Eli M.

Completed cooling tune up, found leak in evaporator coil and gave customer replacement options but she decided to go with bronze refrigerant repair

Near Manchester Ave, Grandview, MO 64030