Kansas City, KS Residential HVAC & Plumbing Services
LBA Heating, Cooling, Plumbing & Electrical was started by people just like you who want and insist on high quality and reliable service. In Kansas City, KS and throughout the Kansas City area, we treat each family and home as if it were our own. That includes rising to the challenge of being a Hero any time the need calls for extraordinary measures.
From routine maintenance to 24/7 emergency repairs, LBA Heating, Cooling, Plumbing & Electrical has you covered for all your home plumbing, heating, and air conditioning needs. The same goes for new and replacement system installations. Read our reviews and find out why your neighbors consider us to be their nearby heating and air company and local plumber in Kansas City, KS.
Recent Jobs and Reviews in Kansas City, KS
Kansas City, KS at a glance
LBA Air Conditioning, Heating & Plumbing has completed 25 jobs in Kansas City, KS between January 2025 and February 2025.
The most recent job was on February 6, 2025.
LBA Air Conditioning, Heating & Plumbing has completed 131 jobs in Kansas City, KS in the last 12 months. The first job there was in December 2014.
Our Local Reviews by City
- Adrian, MO (2)
- Avondale, MO (1)
- Basehor, KS (24)
- Bates City, MO (1)
- Belton, MO (33)
- Blue Springs, MO (72)
- Bonner Springs, KS (30)
- Buckner, MO (1)
- Bucyrus, KS (6)
- Columbia, MO (1)
- De Soto, KS (25)
- Dearborn, MO (1)
- Edwardsville, KS (14)
- Eudora, KS (9)
- Fairway, KS (93)
- Freeman, MO (1)
- Gardner, KS (14)
- Gladstone, MO (65)
- Grain Valley, MO (58)
- Grandview, MO (75)
- Greenwood, MO (3)
- Holt, MO (3)
- Houston Lake, MO (7)
- Independence, MO (184)
- Kansas City, KS (427)
- Kansas City, MO (2902)
- Kearney, MO (3)
- Lake Lotawana, MO (4)
- Lake Quivira, KS (22)
- Lake Waukomis, MO (4)
- Lake Winnebago, MO (1)
- Lansing, KS (2)
- Lawrence, KS (19)
- Leavenworth, KS (8)
- Leawood, KS (429)
- Lee's Summit, MO (164)
- Lenexa, KS (608)
- Liberty, MO (116)
- Lone Jack, MO (1)
- Louisburg, KS (5)
- Merriam, KS (21)
- Mission, KS (204)
- Mission Hills, KS (78)
- North Kansas City, MO (10)
- Northmoor, MO (1)
- Oak Grove, MO (13)
- Odessa, MO (1)
- Olathe, KS (632)
- Ottawa, KS (1)
- Overland Park, KS (1458)
- Paola, KS (1)
- Parkville, MO (191)
- Peculiar, MO (1)
- Platte City, MO (13)
- Pleasant Hill, MO (1)
- Pleasant Valley, MO (4)
- Prairie Village, KS (527)
- Prairie Village New, KS (2)
- Raymore, MO (27)
- Raytown, MO (84)
- Riverside, MO (18)
- Roeland Park, KS (189)
- Shawnee, KS (1045)
- Shawnee Mission, KS (2)
- Smithville, MO (1)
- Spring Hill, KS (13)
- Stilwell, KS (66)
- Sugar Creek, MO (7)
- Weatherby Lake, MO (31)
- Wellsville, KS (1)
- Westwood, KS (30)
- Westwood Hills, KS (18)
Job Locations and Reviews
Upon arrival I began the furnace tune up. First, I ran a static pressure test. This unit is rated for a maximum static pressure of .5 and your system is testing at .6 which is failing over the max allowed. This issues has to do with not having enough air flowing through the system properly. Next, I checked the running amps on the inducer and blower motor. The inducer testing within specs but the blower is overamping which will cause the blower more stress and it will go out sooner than later. I’m also having fluctuating temperature rise. We take the supply air temperature and subtract the return air temp(temp in the home) and check the difference. Your system says it should be between 50 to 80 degrees. I got it within specs at 58 degree split but my temp in the supply keep dropping and then rising again which tells me the blower isn’t pushing the air like it should because of the static pressure failing. I also noticed there is asbestos tape on all the supply runs in the basement. If
Today the heat exchanger in the North Lennox package unit serial 5608H22175 marked as #11 was removed and replaced with a new factory provided heat exchanger. During the repair the flame sensor was cleaned. The unit had its heating functions checked after the repair. The heating functions were then operated via the thermostat and the unit cycles into and out of heat mode properly. Thank you, Jon and Tyler
Sold furnace water heater and duct work
Furnace is leaking carbon monoxide and Hana cracked heat exchanger. Thank you for choosing LBA services!
2-4-25 Boiler tripped off on boiler safety and then some other issues and I think one of the steam traps may be clogged. I need to return tomorrow morning, but the weather is running at this time.
**)*()*)))*)*)*))*)*(*))*()*(&)&*(*)*(&(* Rick, Please change the wording to best fit this scenario, The unit dropped out on high limit. I reset it and it’s back in service, for now. Ty, Jon )*)(&))&())&)(&))&()&)&(&))(&(&)&()&)&)&))& Today I accessed the roof and discovered that rtu #11 was not functioning in heat mode. The cause of this heating outage is that the flame roll-out sensor was tripped. The sensor was renegades and the rooftop unit returned to heating. This sensor is in place to shut down the unit in circumstances such as the condition of this rooftop unit’s heat exchanger. Thank you, Jon.
Completed heating maintenance on all systems
Installed FM2 UV germicidal unit and electrostatic filter
Out today to repair punctures in flue pipe as well as restore gas to water heater. Did so successfully, tested no leaks. Cleaned up work area did not collect. Thank you for choosing LBA services!
Today the hot water heater and three rooftop units were checked. All of the heating and cooling functions are operating. All three rooftop units do need new heat exchangers. The A/Cs were ran and all three rooftop units are moving heat. The temp splits in A/C mode are within range for today’s conditions (40degf and wet). These units are showing signs of their age. Thank you, Jon
remove coil
Estimates for adding an electric water heater or a tankless electric
Inspected water heater went over options, turned over to supervisor
1/29/25 - Completed a light heating maintenance on one RTU. The filters were changed and operation was tested. Overall, the unit was in good condition, it was running well, and there were no issues found at this time.
Installed new Furnace
1/27/25 - Completed a light heating maintenance on all equipment. The filters were changed and operation was tested. Overall, all equipment was in good condition, it was running well, and there were no issues found at this time.
Customer opted for furnace only at this time. Contract signed. 5 space heaters provided.
Customer opted for furnace only at this time. Contract signed. 5 space heaters provided.
Customer opted for furnace only at this time. Contract signed. 5 space heaters provided.
Customer opted for furnace only at this time. Contract signed. 5 space heaters provided.
Dropping off heaters after hours
Went for a furnace inspection today. Did a static pressure test, it failed. Did a carbon monoxide leak test, there is a leak. Heat exchanger is very corroded. The furnace is red tagged and disabled. Thank you for choosing LBA services!
Installed 50 gallon water heater w/ smart AC and pulled and cleaned blower
Upon arrival the homeowner explained the humidifier hasn’t been working. She hasn’t seen any water coming out the drain. At inspection I noticed the water turn valve to the humidifier was stilled turned off. So, I opened it for the correct amount of water flow to the humidifier. It is now working properly. Customer was also having trouble with the filter slot not being large enough to get the filter in and out. I opened the slot better and now the filter will slide with more ease. If you have any questions or concerns please feel free to call us! Your LBA Technician, Tyler Rickard P.S. No payment was due for todays visit. Have a great weekend!
Worked with customer to plan blower wheel maintenance and water heater replacement.