Kansas City, KS Residential HVAC & Plumbing Services
LBA Heating, Cooling, Plumbing & Electrical was started by people just like you who want and insist on high quality and reliable service. In Kansas City, KS and throughout the Kansas City area, we treat each family and home as if it were our own. That includes rising to the challenge of being a Hero any time the need calls for extraordinary measures.
From routine maintenance to 24/7 emergency repairs, LBA Heating, Cooling, Plumbing & Electrical has you covered for all your home plumbing, heating, and air conditioning needs. The same goes for new and replacement system installations. Read our reviews and find out why your neighbors consider us to be their nearby heating and air company and local plumber in Kansas City, KS.
Recent Jobs and Reviews in Kansas City, KS
Kansas City, KS at a glance
LBA Air Conditioning, Heating & Plumbing has completed 25 jobs in Kansas City, KS in February 2025.
The most recent job was on February 14, 2025.
LBA Air Conditioning, Heating & Plumbing has completed 131 jobs in Kansas City, KS in the last 12 months. The first job there was in December 2014.
Our Local Reviews by City
- Adrian, MO (2)
- Avondale, MO (1)
- Basehor, KS (24)
- Bates City, MO (1)
- Belton, MO (33)
- Blue Springs, MO (72)
- Bonner Springs, KS (30)
- Buckner, MO (1)
- Bucyrus, KS (6)
- Columbia, MO (1)
- De Soto, KS (25)
- Dearborn, MO (1)
- Edwardsville, KS (14)
- Eudora, KS (9)
- Fairway, KS (93)
- Freeman, MO (1)
- Gardner, KS (14)
- Gladstone, MO (65)
- Grain Valley, MO (58)
- Grandview, MO (75)
- Greenwood, MO (3)
- Holt, MO (3)
- Houston Lake, MO (7)
- Independence, MO (184)
- Kansas City, KS (427)
- Kansas City, MO (2902)
- Kearney, MO (3)
- Lake Lotawana, MO (4)
- Lake Quivira, KS (22)
- Lake Waukomis, MO (4)
- Lake Winnebago, MO (1)
- Lansing, KS (2)
- Lawrence, KS (19)
- Leavenworth, KS (8)
- Leawood, KS (429)
- Lee's Summit, MO (164)
- Lenexa, KS (608)
- Liberty, MO (116)
- Lone Jack, MO (1)
- Louisburg, KS (5)
- Merriam, KS (21)
- Mission, KS (204)
- Mission Hills, KS (78)
- North Kansas City, MO (10)
- Northmoor, MO (1)
- Oak Grove, MO (13)
- Odessa, MO (1)
- Olathe, KS (632)
- Ottawa, KS (1)
- Overland Park, KS (1458)
- Paola, KS (1)
- Parkville, MO (191)
- Peculiar, MO (1)
- Platte City, MO (13)
- Pleasant Hill, MO (1)
- Pleasant Valley, MO (4)
- Prairie Village, KS (527)
- Prairie Village New, KS (2)
- Raymore, MO (27)
- Raytown, MO (84)
- Riverside, MO (18)
- Roeland Park, KS (189)
- Shawnee, KS (1045)
- Shawnee Mission, KS (2)
- Smithville, MO (1)
- Spring Hill, KS (13)
- Stilwell, KS (66)
- Sugar Creek, MO (7)
- Weatherby Lake, MO (31)
- Wellsville, KS (1)
- Westwood, KS (30)
- Westwood Hills, KS (18)
Job Locations and Reviews
2-15-25 Today’s work Tyler and I Installed filters supply by the customer on all seven rooftop units. Install new blower belt on of the 6 of 7 roortops. With the exception of the Lennox 5 ton unit that has a bad heat exchanger that unit is currently shut down due to bad ignition control and a hole in the heat exchanger,will need to come back and do equipment survey on that unit. No air conditioning systems were checked today RTU#4 installed a new gas valve and temperature limit switch. Time and material 2-14-25 Tyler had 4 hour I had 3.5 hour On 2-13-25 during the no heat call, I found RTU#4+does have a bad gas valve connection and limits and limit switch. This quote is to replace the gas valve and plug and also the temperature limit. Belt will be quoted on a separate ticket
2-3-25 Arrived at the job site at 0806 Tyrone was not on site. I called him myself. He told me, that he had not been called, that we were on our way. I spoke to him. He said he was 45 minutes out, so going to adjust our time for when he actually arrives. Tyrone arrived at 0930. We entered the building. The front lobby was comfortable. The NE office was cold. RTU #7 The area in the center of the building to the north, which I’m calling a kid room was cold RTU #4 When I got up on the roof, the south east sanctuary area. RTU was in ignition lock out. I found the filters were about half clogged. They had day codes on them from 2021 and the belts were extremely loose. I pulled a couple of the filters out of the unit and the unit kept running. Going through the other seven rooftop units I found it all the filters had not been replaced in 2021. They were either partially clogged or half clogged all the have loose belt that need replacement. Both of these issues will affect airflow and tr
Today I used a man basket to access the unit heater that was not functioning. This is the newer unit heater that is located as the N.W. unit out of the four hanging units (s/n 04558). The control board was locked out on a “board failure” alert. The unit was visually checked as well as electrically checked. Below in the tech notes are the items tested and checked. The unit was reset and operating voltages were checked across all safeties and the flame sensor was measured. The unit was cycled through intentional diagnostic faults and responded properly by shutting down and flashing the appropriate error codes for the faults created. The flue pipe was checked for possible ice/snow buildup. The flue pipe was also visually checked from a distance and the flue cap is on and it is venting. The flame sensor was cleaned while I was at the unit and a slight difference in its signal was noted. The heater does signal a flame sensor error when unplugged and not the board failure error
Inspected area for a tankless, planned the route turned over to supervisor
L
L
L
L
High limit switch kept tripping due to a restrictive filter and undersized return drop. After pulling the filter it released the pressure and system was up and running. Thank you for choosing LBA services!
Follow up call to let customer know I went by her house while she was at work today and I found the system is back up and running properly. No new ice had formed and almost all the ice was melted off the outside of the condenser. She said it seemed to be working and keeping the house warm. Advised her to let us know if she has any further issues. Your LBA Technician, Tyler Rickard
Upon arrival we started thawing out the ice on the heat pump. We changed the defrost cycle from 60 seconds to 90 seconds of defrost. Once we got all the ice melted the system ran in heat mode for about an hour and it went into defrost mode as needed. We believe the system is working properly again. I will reach out to the homeowner tomorrow morning to have her check and see if there is any ice built up on the outdoor unit. If you have any questions or concerns please feel free to reach out! Your LBA Technician, Tyler Rickard P.S. No payment due for todays visit. Have a great week!
Out today to perform work proposed. Did so successfully, tested no leaks. Cleaned up work area, homeowner wishes for call to deal with payment. Thank you for choosing LBA services!
Customer called stating system was not satisfying stat. Noticed stat was hitting temp but not satisfying, then tripping on high limit. Changed filter and swapped out thermostat and system is now satisfying. Advised customer to monitor and call for further assistance is needed.
Roll of drain tubing is being sourced, we will reach out to reschedule once we have done so. Thank you for choosing LBA Services!
Roll of drain tubing is being sourced, we will reach out to reschedule once we have done so. Thank you for choosing LBA Services!
Roll of drain tubing is being sourced, we will reach out to reschedule once we have done so. Thank you for choosing LBA Services!
Roll of drain tubing is being sourced, we will reach out to reschedule once we have done so. Thank you for choosing LBA Services!
Upon arrival the heat was not working. Before going inside I checked the heat pump outside and it was completely frozen over I the outside and on the copper pipes inside the unit. I then started diagnosis on system. The thermostat was set to ‘Em. Heat at 70 degees and the temp inside was down at 66 degrees. I went down and took a temperature split and no heating was moving. I hard reset the unit and once it came back on the heat strips engaged and the blower turned on and started heating the home again. I believe 5e heat pump is either low on refrigerant or we have an airflow problem. We installed the electrostatic filter into the system about 10 days ago. I tested the system with the electrostatic filter and without it. It worked both ways. I think when the heat pump froze over and stopped working the system didn’t receive the message for the heat strips to take over and engage for heat. After resetting the system I didn’t have any further issues. I got the supply air temp up to 96 d
Went for a maintenance call today. Tested for static pressure and is passing. Did a carbon monoxide test, no co was detected when testing. Inspected heat exchanger did notice rust spots. Due to when coil was frozen and dethawed. Water got to the heat exchanger. Notified customer and is aware of situation. All electrical components are passing for system. Temp split is passing for system. Did clean flame sensor and pressure switch hose. Did notice blower wheel is collecting a lot of dust. Will recommend for a clean. No further wear and tear. Thank you for choosing LBA services-Johann.
Out today for kinked drain line on Novo softener and purity unit. Upon inspection discovered that unit has been draining fine during regeneration, however half inch drain tubing is inadequately sized for the extended run of drain tubing to the floor drain. We will just have to return and go back with three-quarter inch reinforced stainless steel plastic tubing cleaned up work area and did not collect. We will return Monday morning or schedule accordingly. Thank you for choosing LBA services!
Sold g disposal
Inspected leaking sink turned over tomsupervisor
.
Smart ac sensors are working now
Installed new Furnace model FR801T075417UHSNA, Boot & Drop, new water heater w/ expansion tank