Call LBA Services Book Online Contact Us

Kansas City, KS HVAC & Plumbing Services

Lba Services Kansas City Hvac Plumbing Kc

Kansas City, KS Residential HVAC & Plumbing Services

LBA Heating, Cooling, Plumbing & Electrical was started by people just like you who want and insist on high quality and reliable service. In Kansas City, KS and throughout the Kansas City area, we treat each family and home as if it were our own. That includes rising to the challenge of being a Hero any time the need calls for extraordinary measures.

From routine maintenance to 24/7 emergency repairs, LBA Heating, Cooling, Plumbing & Electrical has you covered for all your home plumbing, heating, and air conditioning needs. The same goes for new and replacement system installations. Read our reviews and find out why your neighbors consider us to be their nearby heating and air company and local plumber in Kansas City, KS.

Recent Jobs and Reviews in Kansas City, KS

Rated 4.8 out of 5 stars based on 427 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction with the service provided. Customers consistently express appreciation for the professionalism, efficiency, and expertise demonstrated by the technicians. Recurring themes include prompt and timely service, with many reviewers highlighting how quickly issues were diagnosed and resolved. The technicians are frequently praised for being friendly, courteous, and communicative, taking the time to thoroughly explain problems and solutions in clear, understandable terms. Many customers specifically mention feeling confident that they were not being upsold unnecessary services, which they found refreshing and trustworthy. The quality of workmanship receives high marks, with reviewers noting thorough inspections, attention to detail, and jobs completed efficiently—often within hours. Several customers express gratitude for cost-effective solutions and fair pricing, with some noting significant savings compared to other estimates. The membership and maintenance programs are highlighted as providing excellent value and peace of mind. Overall, the tone is enthusiastic and appreciative, with many reviewers stating they would highly recommend the service to others and plan to use the company again in the future. The sentiment reflects a customer base that feels well-served, respected, and confident in the technical abilities and integrity of the service providers.

Kansas City, KS at a glance

LBA Air Conditioning, Heating & Plumbing has completed 25 jobs in Kansas City, KS in February 2025.

The most recent job was on February 20, 2025.

LBA Air Conditioning, Heating & Plumbing has completed 131 jobs in Kansas City, KS in the last 12 months. The first job there was in December 2014.

Job Locations and Reviews

Nick L.
Nick L. Checked in
Follow up 5:30
Kansas City, KS 66103
JJ H.
JJ H. Checked in
Went for a furnace inspection today. Did a static pressure test, it failed. Did a combustion analysis test, it passed. Inducer motor is over amping. Heat exchanger and the burners are extremely rusted. Gas pressure and pressure switch passed. Temp split between the supply and return duct passed. Blower motor amperage is passing and blower wheel is dirty. Thank you for choosing LBA services!
Kansas City, KS 66103
.
. Checked in
Today I arrived and Dean relayed to me that the breakroom for the recycling plant was blowing cold air. I checked the breakroom and there was warm air exiting the supply vents. One foot below the ceiling of the breakroom measured 80 deg and the room temp was 57. This room has no insulation and exterior walls as well as the floor has no insulation and is exposed to the outdoor temp (8degf). I did recommend a fan be put in the breakroom to move some of the heated air off of the ceiling. In addition to this Dean and I checked the areas that the other rooftop unit serves (bathrooms) and the rooftop unit for the bathrooms is not functioning. The both bathrooms have frozen pipes as there were secondary heaters in the bathrooms but they are now missing. Dean requested that I and his employees do not use the lift and access the roof due to snow and ice. He would like us to contact him on Monday to schedule a service call for the rooftop unit that serves the bathrooms. Thank you, Jon
Kansas City, KS 66111
Richard H.
Richard H. Checked in
Estimate
Kansas City, KS 66103
Nick L.
Nick L. Checked in
Decline
Kansas City, KS 66103
Chase P.
Chase P. Checked in
Filter hadn’t been changed for a year. It was stopping the system from running properly. Customer will go buy new filter. Exhaust is leaking. They would like to talk about fixing it before going with it. Recommended maintenance on the system as well and mentioned membership to them.
Kansas City, KS 66109
Tyler R.
Tyler R. Checked in
Upon arrival the homeowner told me they were interested in having the ducts cleaned. They had another company out and told them the unit wasn’t working properly because the ducts were too dirty to move the air through the system. I started my diagnostics. First, I ran a static pressure test. This unit is rated for a max static pressure of .5 and it is currently testing at 1.2 which is over double the specifications. Next, I checked the temperatures. The supply air temp was at 125 degrees (minus) the return air temp of 62 degrees giving us a difference of 63 degrees. The manufacturer wants the temp differential to be between 30 to 60 degrees and we are over that temp which is causing the system to overheat and short cycle over and over putting lots of strain on the system. My Field Supervisor Nick arrived to help find a solution for the homeowner. If you have any questions or concerns please feel free to contact us! Your LBA Technician, Tyler Rickard P.S. No payment was due for todays v
Kansas City, KS 66103
Steve R.
Steve R. Checked in
2-19-2 Two unit heater is in the back you’re not working I have a control board. I will call to pick up in the morning.
Kansas City, KS 66111
.
. Checked in
Today I spoke with Michael when I arrived. He relayed to me that one of the unit heaters is not working. The other hanging heater, he said it has been out of service for awhile. The unit heater that was not working was diagnosed as having a bad gas valve. Due to the condition and age of the units I did offer to not repair the unit and gather information for a replacement. Replacing the failed gas valve was verbally approved by Michael. The heater was visually checked, the flue pipe was checked, and the safeties were confirmed to be in operating condition. The gas valve for the unit was sourced, picked up and installed today. After the gas valve was installed the gas pressure was adjusted and rechecked. The fan motor was checked and the bearings as well as the capacitor and amp draw were ok. The gas pressure was rechecked and adjusted. Due to the age and condition of these unit heaters information was gathered for a replacement estimate. Thank you, Jon Tech notes: reznor
Kansas City, KS 66106
Steve R.
Steve R. Checked in
2-17-25 No heat in the cafeteria. Found the 1986 Lennox furnace pilot was out when I re-lit the pilot. It was real weak. I was able to pull and clean the pilot reinstall. Start the furnace. I went ahead and did a combustion analyzer on it the center and two right hand burners. I’ve got extremely high CO I shut this one down. The other furnace in the area feeds the back end of the cafeteria that one was running however, there was no fire, and it had a code of the high limit switch is tripped, found the fire damper on the supply below the evaporator coil. This is a downflow furnace is shut. I cannot access it without cutting the sheet metal or pulling the evaporator coil. I left a message with Bob and Ryan. I will get with them tomorrow and see how we’re gonna go forward.
Kansas City, KS 66111
Josiah W.
Josiah W. Checked in
M
Kansas City, KS 66112
Josiah W.
Josiah W. Checked in
Inspected shower valve turned over to supervisor
Kansas City, KS 66112
Steve R.
Steve R. Checked in
2-17-25 Customer wants full condition report of HVAC system, exhaust hoods, and walk in fridges Walk-in freezer Checked the operation of the unit Upon arrival the walk-in freezer was shut down, located circuit breakers. Turn the system on and let it settle out. Set the thermostat @ -4° system is running condenser has little bit of rattle. Sightglass glass its clear. Condenser fan motor it’s good Visual inspection for oil leaks. It’s all good. evaporator fan motors look good. Check the electrical connections are good Check the defrost timer good Check defrost termination control is good Checked the evaporator heaters and the pan heaters The condensate line heater is working System did bring the temperature down to -4° and then cycled off One issue I found was there is no P-trap on the condensate drain on the system. Walk-in Cooler Upon arrival the walk-in cooler was shut down, located circuit breakers. Turn the system on and let it settle out. Set thermostat @ 35° Sightglass glas
Kansas City, KS 66106
Andrew S.
Andrew S. Checked in
Arrived for a follow up from Friday. System was not heating properly. Thermostat is on second floor, which is causing the main floor to not heat as well. Filter was very dirty and causing airflow issues. Checked heat pump outside and it’s working. Thermostat was not programmed 100% correct and I set it correct. System is heating correct.
Kansas City, KS 66109
Johann A.
Johann A. Checked in
Went for a maintenance call today. Tested for static pressure, system is at max rating. Did a co test, no co was detected when testing. Inspected heat exchanger no wear and tear. Did notice evaporator coil has biological growth. When inspecting heat exchanger. Temp split is passing for system. All electrical components are passing for manufacture specifications. Did clean flame sensor and pressure switch hose. No further wear and tear on system.
Kansas City, KS 66104
Nick L.
Nick L. Checked in
Didn’t present follow up in may
Kansas City, KS 66104
Scott M.
Scott M. Checked in
N
Kansas City, KS 66106
Scott M.
Scott M. Checked in
N
Kansas City, KS 66106
Scott M.
Scott M. Checked in
N
Kansas City, KS 66106
Scott M.
Scott M. Checked in
N
Kansas City, KS 66106
Tyler R.
Tyler R. Checked in
Upon arrival i noticed the main level floor was extremely cold. The homeowner explained that the upstairs has been staying much warmer than the main floor level. She had a temp gauge and showed me the temp in the kitchen was at 52 degrees while the upstairs thermostat read 63 degrees. Upon inspection I found to heat pump starting to freeze over, along with the evaporator coil inside. I shut down the heat pump and switched into Emergency Heat so that I could start melting the coil and start warming up the house. We will have to come back out on Monday to unthaw the heat pump if necessary and get it back up and running again. I have the system set to only run in emergency heat mode for this weekend which should keep the house plenty warm. If you guys have any questions or concerns please feel free to reach out! Your LBA Technician, Tyler Rickard P.S. No payment was due for todays visit. Have a great weekend!
Kansas City, KS 66109
Tucker R.
Tucker R. Checked in
Installed new water softener and tankless water heater and ran a home run to breaker box.
Kansas City, KS 66111
Johann A.
Johann A. Checked in
Went for a maintenance today. When going to air handler, all electrical components are passing when testing. Temp split is passing as well. Did notice blower wheel is collecting dust on the wheel and building up. Did test for static pressure and is reading high for manufacture specifications. Went outside compressor and fan are passing in amperage. Capacitor is passing for both air handler and condenser. No further wear and tear. Thank you for choosing LBA.
Kansas City, KS 66109
Ramon O.
Ramon O. Checked in
Came out here for a furnace tuneup. Upon arrival tested static static was good. Static has been improved to a passing rating took within the ductwork for carbon monoxide meter ran a zero as well as did a combustion analyzer test. All numbers within the test were perfectly within range cleaned out flame sensor filter has already been replaced insured the operations within the heating cycle working perfectly fine. Thank you for choosing LB.
Kansas City, KS 66102
Adam M.
Adam M. Checked in
Customer declined static discussion to improve failed static measurements. Explained to him the blower wheel is dirty and will continue to get worse if static is not addressed. Recommended and estimated blower wheel cleaning. Following up next week.
Kansas City, KS 66109
lba-services-group

Check Out Our Five-Star Reviews

Award Winning Service
Request Service
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon

Call For Same Day Service/Emergencies at 913-268-6822 .

By pressing “Submit,” I agree to receive information & promotional text messages from LBA Air Conditioning, Heating, & Plumbing, Inc. Msg & data rates may apply. Message frequency may vary. Reply STOP to opt out, HELP for help. View our Terms & Conditions and Privacy Policy. Consent is not a condition of purchase.
By pressing “Submit,” I agree to receive information & promotional text messages from LBA Air Conditioning, Heating, & Plumbing, Inc. Msg & data rates may apply. Message frequency may vary. Reply STOP to opt out, HELP for help. View our Privacy Policy at https://www.lbaservices.com/privacy-policy/ and our Terms & Conditions at https://www.lbaservices.com/terms-and-conditions/. Consent is not a condition of purchase.
I Agree
Back Next