Kansas City, KS Residential HVAC & Plumbing Services
LBA Heating, Cooling, Plumbing & Electrical was started by people just like you who want and insist on high quality and reliable service. In Kansas City, KS and throughout the Kansas City area, we treat each family and home as if it were our own. That includes rising to the challenge of being a Hero any time the need calls for extraordinary measures.
From routine maintenance to 24/7 emergency repairs, LBA Heating, Cooling, Plumbing & Electrical has you covered for all your home plumbing, heating, and air conditioning needs. The same goes for new and replacement system installations. Read our reviews and find out why your neighbors consider us to be their nearby heating and air company and local plumber in Kansas City, KS.
Recent Jobs and Reviews in Kansas City, KS
Kansas City, KS at a glance
LBA Air Conditioning, Heating & Plumbing has completed 25 jobs in Kansas City, KS in November 2024.
The most recent job was on November 11, 2024.
LBA Air Conditioning, Heating & Plumbing has completed 131 jobs in Kansas City, KS in the last 12 months. The first job there was in December 2014.
Our Local Reviews by City
- Adrian, MO (2)
- Avondale, MO (1)
- Basehor, KS (24)
- Bates City, MO (1)
- Belton, MO (33)
- Blue Springs, MO (72)
- Bonner Springs, KS (30)
- Buckner, MO (1)
- Bucyrus, KS (6)
- Columbia, MO (1)
- De Soto, KS (25)
- Dearborn, MO (1)
- Edwardsville, KS (14)
- Eudora, KS (9)
- Fairway, KS (93)
- Freeman, MO (1)
- Gardner, KS (14)
- Gladstone, MO (65)
- Grain Valley, MO (58)
- Grandview, MO (75)
- Greenwood, MO (3)
- Holt, MO (3)
- Houston Lake, MO (7)
- Independence, MO (184)
- Kansas City, KS (427)
- Kansas City, MO (2902)
- Kearney, MO (3)
- Lake Lotawana, MO (4)
- Lake Quivira, KS (22)
- Lake Waukomis, MO (4)
- Lake Winnebago, MO (1)
- Lansing, KS (2)
- Lawrence, KS (19)
- Leavenworth, KS (8)
- Leawood, KS (429)
- Lee's Summit, MO (164)
- Lenexa, KS (608)
- Liberty, MO (116)
- Lone Jack, MO (1)
- Louisburg, KS (5)
- Merriam, KS (21)
- Mission, KS (204)
- Mission Hills, KS (78)
- North Kansas City, MO (10)
- Northmoor, MO (1)
- Oak Grove, MO (13)
- Odessa, MO (1)
- Olathe, KS (632)
- Ottawa, KS (1)
- Overland Park, KS (1458)
- Paola, KS (1)
- Parkville, MO (191)
- Peculiar, MO (1)
- Platte City, MO (13)
- Pleasant Hill, MO (1)
- Pleasant Valley, MO (4)
- Prairie Village, KS (527)
- Prairie Village New, KS (2)
- Raymore, MO (27)
- Raytown, MO (84)
- Riverside, MO (18)
- Roeland Park, KS (189)
- Shawnee, KS (1045)
- Shawnee Mission, KS (2)
- Smithville, MO (1)
- Spring Hill, KS (13)
- Stilwell, KS (66)
- Sugar Creek, MO (7)
- Weatherby Lake, MO (31)
- Wellsville, KS (1)
- Westwood, KS (30)
- Westwood Hills, KS (18)
Job Locations and Reviews
Na
Upon arrival I began the furnace tune up. First,I did a static pressure test. System is testing at .6 total and the manufacturer has this system set for a maximum of .5 which is currently failing. I then checked the heat exchanger because last time I was here I found a crack in the heat exchanger. I looked over the heat exchanger really well and I found a 2nd and 3rd crack in the heat exchanger which means it will leak CO into the home if you run the heat right now. I have turned the gas to the furnace off so that you don’t accidentally turn it on. The blower wheel is very dirty and has accumulated a lot of dust and debris over the last 20 years. I had to put a “red tag” on the furnace stating it should not be turned on by anyone other than a licensed hvac technician. My Field Supervisor Scott is talking with the homeowners about replacing the furnace. If you have any questions or concerns please feel free to contact us. Have a great week ahead! Your LBA Technician, Tyler Rickard P.S.
Estimate
Gathered CFM count. Customer just upgraded ducts this past spring. Possible IAQ upgrades in future.
Completed furnace inspection for customer. All aspects of system tested within manufacturer specifications. No recommendations at this time.
Shelly approved the heat exchanger replacement option. She requested the system remain disassembled until the replacement was installed. Furnace flue rebuild included in the service. Combustion analysis will be conducted to ensure the furnace is running at the required temperature for efficiency and to prevent the condensation issues that corroded the old exhaust flue.
TO
11/11/24 Today the existing heat exchanger was removed and a new factory sourced heat exchanger was installed. The new heat exchanger was inspected before install. After the replacement was completed the gas pressure and temperatures were checked and are within the manufacturer’s specifications. The heating functions returned to normal operation after the repair was completed. Thank you, Jon Tech notes: Lennox, low fire 1.6 , high fire 3.6 Replace the failed heat exchanger in the Lennox package unit serial 5615K05633. The heat exchanger is under the factory warranty of ten years that will expire in November 2025. Customer is responsible for the labor to replace the heat exchanger. The heating mode has been disabled for safety to prevent carbon monoxide from entering the conditioned space the unit serves. Price includes labor and returning the failed exchanger for warranty reimbursement.
Arrived to customer for a furnace tuneup in during the inspection. We will see the high call on static pressure along with discovering a dirty blower wheel and the gas line leak. Other than that all other components met within factory specs.
Static passing after adjustments. Gas leak discovered. Repair scheduled for Friday.
Completed full heating maintenance
Sold job for tuesday
Work to be completed on Tuesday. Financing applied
11-8-24 Check the couple of the make up air units. There is a total of six. All of them have clogged pre-filters, flame sensor and flame, ignition rods need to be pulled and cleaned. Blower wheels need to be greased.The two I looked at the belts look good. We’re gonna have to get up here in a warmer day the hose out the pre-filters and also there are some extra pre-filters up on the roof. We can hose them out also just kind of back up. It’s the end of the day Bob had already left, but we let them know that we need. We got a lot of work here to work on his units.. I didn’t look at any of the exhaust fans up there, but they they were all off.
Replace the Janitrol unit heater serial 89GH3790R for the warehouse. Price includes a Lennox 125,000 btu gas fired unit heater and a solid state room thermostat. Existing utilities will be reused.
Arrived for furnace maintenance on one of your systems. I did the upstairs system today. Checked static pressure and found it was below the max rating. Ran carbon monoxide test and the reading was 0ppm. Heat exchanger looked good today. All electrical components are running properly at this time. Blower wheel is starting to collect dust and will need to be cleaned soon. The two electrostatic filters are clean so I did not change them. With approval I did replace the humidifier panel. System is running upon departure. Thanks for choosing LBA.
Estimate
X
Completed furnace maintenance for customer. All aspects of system tested within manufacturer specifications. No recommendations at this time.
Replace furnace
11-6-24 New gas valve came in picked up gas stuff at the supply house confirmed the right valve and will schedule to install The needed repairs were found 10-25-24 This bid is to install new second redundant safety gas valve. Access the burner area and clean the burners and pilot assy I will also check my gas pressures. Confirm all those are working right before putting the system back online. AJAX Hot water boiler Model WG-1750 D Serial 86-38673
Customer requested estimates for system replacement and possible modifications for improvement. Old equipment has failed and is inoperable or unsafe to operate. Compressor is grounded and heat exchanger in furnace is leaking Carbon monoxide. Field supervisor is advising customer on options to replace.
Goodman furnace, 80% nat gas, m/n GMS80403ANBC, s/n 1410161710–Remove and clean the inducer assembly to remove rust from a previous flue repairs. *11/05/24, Completed. Goodman a/c only condenser, m/n GSX130301BD, s/n 1504111542–Leak search the system to locate the cause of the low charge condition. Verify the compressor is operating at capacity due to the excessive noise while running. Price does not include new refrigerant. New refrigerant will be quoted separately after locating the leak. Carrier package unit, m/n 48TCED08A2A5AOAOGO, s/n 3118P30506–Replace the filters. International comfort products package unit, m/n PGF348120k00A1, s/n G063351231–Clean the burners, flame sensor and spark electrode. Replace the compressor contactor and verify the refrigerant charge. *11/05/24, Completed, burners pulled and cleaned. Flame sensor and spark ignition also cleaned. Need a transformer Janitrol unit heater m/n WH-100, s/n 89GH3790R– Replacement quote will be sent separately.
Installed new Full System, new programmable thermostat and new AA600 Humidifier Furnace Model # FR801T0503A14UHSNA, AC Unit Model # FRA14AZ24AJ1NA, Evap Coil Model # FTCFZ2414STAAMC *10 year parts warranty *10 year labor warranty *LIFETIME NO HASSLE REPLACEMENT WARRANTY PROTECTING YOU FROM FAILURE OF HEAT EXCHANR AND COMPRESSOR!
Static decline