Kansas City, KS Residential HVAC & Plumbing Services
LBA Heating, Cooling, Plumbing & Electrical was started by people just like you who want and insist on high quality and reliable service. In Kansas City, KS and throughout the Kansas City area, we treat each family and home as if it were our own. That includes rising to the challenge of being a Hero any time the need calls for extraordinary measures.
From routine maintenance to 24/7 emergency repairs, LBA Heating, Cooling, Plumbing & Electrical has you covered for all your home plumbing, heating, and air conditioning needs. The same goes for new and replacement system installations. Read our reviews and find out why your neighbors consider us to be their nearby heating and air company and local plumber in Kansas City, KS.
Recent Jobs and Reviews in Kansas City, KS
Kansas City, KS at a glance
LBA Air Conditioning, Heating & Plumbing has completed 25 jobs in Kansas City, KS in December 2024.
The most recent job was on December 16, 2024.
LBA Air Conditioning, Heating & Plumbing has completed 131 jobs in Kansas City, KS in the last 12 months. The first job there was in December 2014.
Our Local Reviews by City
- Adrian, MO (2)
- Avondale, MO (1)
- Basehor, KS (24)
- Bates City, MO (1)
- Belton, MO (33)
- Blue Springs, MO (72)
- Bonner Springs, KS (30)
- Buckner, MO (1)
- Bucyrus, KS (6)
- Columbia, MO (1)
- De Soto, KS (25)
- Dearborn, MO (1)
- Edwardsville, KS (14)
- Eudora, KS (9)
- Fairway, KS (93)
- Freeman, MO (1)
- Gardner, KS (14)
- Gladstone, MO (65)
- Grain Valley, MO (58)
- Grandview, MO (75)
- Greenwood, MO (3)
- Holt, MO (3)
- Houston Lake, MO (7)
- Independence, MO (184)
- Kansas City, KS (427)
- Kansas City, MO (2902)
- Kearney, MO (3)
- Lake Lotawana, MO (4)
- Lake Quivira, KS (22)
- Lake Waukomis, MO (4)
- Lake Winnebago, MO (1)
- Lansing, KS (2)
- Lawrence, KS (19)
- Leavenworth, KS (8)
- Leawood, KS (429)
- Lee's Summit, MO (164)
- Lenexa, KS (608)
- Liberty, MO (116)
- Lone Jack, MO (1)
- Louisburg, KS (5)
- Merriam, KS (21)
- Mission, KS (204)
- Mission Hills, KS (78)
- North Kansas City, MO (10)
- Northmoor, MO (1)
- Oak Grove, MO (13)
- Odessa, MO (1)
- Olathe, KS (632)
- Ottawa, KS (1)
- Overland Park, KS (1458)
- Paola, KS (1)
- Parkville, MO (191)
- Peculiar, MO (1)
- Platte City, MO (13)
- Pleasant Hill, MO (1)
- Pleasant Valley, MO (4)
- Prairie Village, KS (527)
- Prairie Village New, KS (2)
- Raymore, MO (27)
- Raytown, MO (84)
- Riverside, MO (18)
- Roeland Park, KS (189)
- Shawnee, KS (1045)
- Shawnee Mission, KS (2)
- Smithville, MO (1)
- Spring Hill, KS (13)
- Stilwell, KS (66)
- Sugar Creek, MO (7)
- Weatherby Lake, MO (31)
- Wellsville, KS (1)
- Westwood, KS (30)
- Westwood Hills, KS (18)
Job Locations and Reviews
floor c/o in basement 4" clay tile 10-55 ft is wide open, no roots, break or water At 59 ft camera goes under water At 64 ft I hit roots and loaded line, tissue and wipes Owner is in contract selling home Wants line jetted
A:11
Fitting is still bleeding pressure and had to pump up system again. Boiler is operating now but will need to return to make a repair. Contacted office regarding return visit.
12-11-24 The chapel, has six steam heat wall units, 3 on each side. The right hand first unit is making a hissing sound found a steam leak at the union below the solenoid valve. I’m gonna have to return on this one. I’ve gotta pick up some parts. for now. Today I closed the ball valves. In the left side the center unit its blowing cold air I was able to exercise the isolation valve manually and get it to work. Also, the third one is doing the same thing. I will recheck these again when I come through the steam leak repair. The third floor bathroom washroom is reported that there was water on the floor underneath the radiator. We ran it and cycled it didn’t find any leaks. Also, the unit is working. The third floor bedroom I don’t have the exact number. that also I had to exercise the isolation valve and that one has been cycling fine. Down in the border of the room, the chemical feed tubing had a small leak in it. I got a hold of the chemical company and they came out and replace
Completed turnace maintenance and inspection. I checked airflow and temp splits. I tested for carbon monoxide and found none. Furnace is 4 yrs old. Furnace is running within manufacture specifications. I spoke with customer about ductwork and the dirt getting into the system. Eventually customer would like to have ductwork fixed and blower compartment cleaned out at the same time.
DATE: 12/10/24 Detailed description of what was done today: arrived at home and spoke with Brian about reason I was called today, for a kitchen sink that was clogged. After doing inspection of sink and pipe I had him sign off on our drain clearing special before getting started. I ran 65 to 75 feet of cable hallway to main stack and ran line inside to scrape the sides of pipe. After removing pipe out, I ran water which was flowing properly for about one minute. Then suddenly started to fill up again, I took P-trap off again, and ran back back down one more time for a little bit longer. After second, running with backpack, his line was opened up from all the grease that was in his. I let them know that if we have to come back out, it would be myself and another supervisor, because the grease it doesn’t just go away overnight. After collected payment and signatures, I cleaned up and headed out. Wear and Tear: -Drain clearing special . After reviewing the entire house I went over ever
12-10-24 Make up air units # 3,6 and 4 are not heating Units 3 and 6 were tripped off the high temperature limit, which is set @ 170° reset limit unit to running this time. We may have issues with dirty blower wheel. Unit # 4 The belts are off the pulley. Thr pulley are out of alignment by probably a good half inch I made those adjustments then I picked up new belts and installed checked. I went ahead and heavily grease the blower wheel bearings. Unit #6 Start again by the high limit I checked the temperature at the limit. It’s raining about 168 and the limit is at 175°. This could be airflow it could be a number of things. I did check the modulating gas valve and its controls. It seems to be running on constant high fire no matter what. For right now, I made some temporary adjustments so the unit runs about 135°. That is with Bob that needs to return to troubleshoot this one more. I may be having the same issue with unit number three which also tripped off on high limit, but I d
Estimate
One unit heater in the soap room for the wash bay serial 5199 has a locked inducer motor. The other unit is in the small wash bay on the north side of the truck wash building serial. 7008 has a bad gas valve. I order the parts from Lennox and will be shipped to the shop by end of this week and will need to return to install.
Arrived to remedy a system that is making excessive noise. Upon arrival homeowner mentioned that the system will make a popping noise when the fan would turn on and off. Upon inspection of the unit found water pouring out of the humidifier and humidifier drain. Restricted the humidifier water flow to keep water off the ground. Tried to recreate the noise the homeowner was talking about and was not successful. Turned the humidifier water back to full open and operated the humidistat to turn the humidifier on and off. Found that the solenoid valve would make a hammering noise when it would turn on and off. Set the water valve back to 25% open in an effort to prevent this. Installed a homeowner provided water panel and installed a metering orifice to make sure the system isn’t wasting excessive water. Tested system operations. Furnace is functioning properly at this time.
12/9/24 - Completed a full heating maintenance on one RTU. The filter size needed was (4) 16x20x2, but they have now been replaced. The heat exchanger was breeched, so the gas was shut off the unit. The unit did heat properly when tested, but it will not be heating until the heat exchanger is replaced.
system
Upon arrival I began the furnace tune up. First, I did a static pressure test on the system. This system is rated for a maximum static pressure of .5 and your system is testing at .48 which is below the maximum. Next, I checked the running amps on the inducer and blower motor and both were testing within specifications. I changed out the filter on the left side today which was a size 20x25x1 inch high velocity filter. The other filter on the right side was still clean today and it’s a size 20x25x4 inch filter. The temperature split in the house was within specifications at 47 degrees. If you have any questions or concerns please feel free to call us! Your LBA Technician, Tyler Rickard P.S. No payment was due today, it was covered with your membership. Have a great weekend!
Fixed thermostat.
Relit water heater
Call
Sent quotes for repair and replacement
Full System, FM1, EcoNet
Draft inducer motor failing upon arrival. Replaced failing motor and fired system up. Upon firing the system up, we found a carbon monoxide leak due to a crack in the heat exchanger. If customer wants to replace furnace, we will credit the money spent today towards a new furnace that would come with a 10 year part and 10 year labor warranty.
Inducer replaced. Started up furnace, did a carbon monoxide leak test, there is a leak. The furnace is red tagged and gas is shut off to it. Thank you for choosing LBA services!
Arrived to do a performance maintenance. Set up for combustion analysis temperature split and static pressure tests. Verified operation of all mechanical and electronic components of the furnace. Checked blower for cleanliness and to see if there is any play in the bearings. Found it coated in dust debris. Checked systems heat exchanger to ensure proper venting of flue gas. Found bacterial growth present on the evaporator’s condensation pan. Found that the home is sitting at 23% humidity. Performed an electronic gas leak search. Spoke with homeowner about the system. Furnace is operational at this time.
Clogged drain. Thank you for choosing LBA services!
Repair gas leak, cut out old fitting that was leaking. Pressed in new union coupling to allow future service to gas system. Checked for leaks with micro bubbles and electronic detector with no leaks present.
Sold full system
Arrived for furnace maintenance today. Upon inspection I found that the inducer motor is leaking. I checked the heat exchanger and found bad rusting on the tubes. Raymond wanted a field supervisor out to discuss replacement options. Thanks for choosing LBA.