Independence, MO Residential HVAC & Plumbing Services
LBA Heating, Cooling, Plumbing & Electrical was started by people just like you who want and insist on high quality and reliable service. In Independence, MO and throughout the Kansas City area, we treat each family and home as if it were our own. That includes rising to the challenge of being a Hero any time the need calls for extraordinary measures.
From routine maintenance to 24/7 emergency repairs, LBA Heating, Cooling, Plumbing & Electrical has you covered for all your home plumbing, heating, and air conditioning needs. The same goes for new and replacement system installations. Read our reviews and find out why your neighbors consider us to be their nearby heating and air company and local plumber in Independence, MO.
Recent Jobs and Reviews in Independence, MO
Independence, MO at a glance
LBA Air Conditioning, Heating & Plumbing has completed 25 jobs in Independence, MO between December 2024 and January 2025.
The most recent job was on January 9, 2025.
LBA Air Conditioning, Heating & Plumbing has completed 59 jobs in Independence, MO in the last 12 months. The first job there was in January 2015.
Our Local Reviews by City
- Adrian, MO (2)
- Avondale, MO (1)
- Basehor, KS (24)
- Bates City, MO (1)
- Belton, MO (33)
- Blue Springs, MO (72)
- Bonner Springs, KS (30)
- Buckner, MO (1)
- Bucyrus, KS (6)
- Columbia, MO (1)
- De Soto, KS (25)
- Dearborn, MO (1)
- Edwardsville, KS (14)
- Eudora, KS (9)
- Fairway, KS (93)
- Freeman, MO (1)
- Gardner, KS (14)
- Gladstone, MO (65)
- Grain Valley, MO (58)
- Grandview, MO (75)
- Greenwood, MO (3)
- Holt, MO (3)
- Houston Lake, MO (7)
- Independence, MO (184)
- Kansas City, KS (427)
- Kansas City, MO (2902)
- Kearney, MO (3)
- Lake Lotawana, MO (4)
- Lake Quivira, KS (22)
- Lake Waukomis, MO (4)
- Lake Winnebago, MO (1)
- Lansing, KS (2)
- Lawrence, KS (19)
- Leavenworth, KS (8)
- Leawood, KS (429)
- Lee's Summit, MO (164)
- Lenexa, KS (608)
- Liberty, MO (116)
- Lone Jack, MO (1)
- Louisburg, KS (5)
- Merriam, KS (21)
- Mission, KS (204)
- Mission Hills, KS (78)
- North Kansas City, MO (10)
- Northmoor, MO (1)
- Oak Grove, MO (13)
- Odessa, MO (1)
- Olathe, KS (632)
- Ottawa, KS (1)
- Overland Park, KS (1458)
- Paola, KS (1)
- Parkville, MO (191)
- Peculiar, MO (1)
- Platte City, MO (13)
- Pleasant Hill, MO (1)
- Pleasant Valley, MO (4)
- Prairie Village, KS (527)
- Prairie Village New, KS (2)
- Raymore, MO (27)
- Raytown, MO (84)
- Riverside, MO (18)
- Roeland Park, KS (189)
- Shawnee, KS (1045)
- Shawnee Mission, KS (2)
- Smithville, MO (1)
- Spring Hill, KS (13)
- Stilwell, KS (66)
- Sugar Creek, MO (7)
- Weatherby Lake, MO (31)
- Wellsville, KS (1)
- Westwood, KS (30)
- Westwood Hills, KS (18)
Job Locations and Reviews
Arrived for furnace maintenance today. Checked static pressure and found it is passing at this time. Carbon monoxide test was 0ppm. Heat exchanger looks good right now. I replaced furnace filter. Blower wheel is starting to collect dust. All electrical components are running properly at this time. Humidifier is running properly. System is running upon departure. Thanks for choosing LBA.
1/9/25 - Completed a light maintenance on four RTU’s. All filters were changed and operation was tested. Overall, all units seemed to be in good condition, they were running well, and there were no issues found at this time.
Service financed kitchen sink line reroute
Inspected sink turned over to supervisor
1/9/25 - The filters have been picked up, but the location was once again closed, so we will need to return to complete the maintenance.
Arrive to customers for a furnace tuneup, and during the process of the inspection, we discovered a dirty blower wheel along with a dirty filter. All other components met within factory specs.
S
See notes
S
Arrived to customers for a furnace inspection in during the process we received a high call on static pressure Along with discovering a dirty blower wheel, dirty filter. All other components met within factory specs.
I called the Goodman Parts Department and they found a heat exchanger that is located in Ohio. The delivery time is 7 to 10 business days. The parts department told me that because of the bad weather we have coming in, it could affect the delivery time possibly. They will contact us as soon as they have the part in hand. Then we can pick up and schedule a time to come and install. If you have any questions or concerns please feel free to call the office or Jamie. Jamie will be calling you very soon this morning. Your LBA Technician, Tyler Rickard P.S. you will need to keep an eye on your water and plumbing pipes in your home. When it’s gets really cold you will need to try and make sure your pipes don’t freeze and burst. Have a great New Year!
Increase supply and return ductwork volume to meet static pressure requirements *2 stage 96% furnace *10 yr parts *10 yr labor- w/airflow correction
.
Upon arrival I began the furnace tune up. First, I ran a static pressure test on the system. This unit has a maximum rating of .5 static pressure. When I tested the system in 1st stage heating the static tested at .51 & when I tested the system in 2nd stage heat it was failing at .75 static pressure. My Field Supervisor Kincaid is here to figure out why the static is failing. Next, I checked the running amps on the inducer and blower motor and both tested within manufacturer specifications. Lastly, I took a temperature differential. The temp rise should be between 30 to 60 degrees. Your system is testing at (Supply temp) 119 degrees (-) (Return temp) 75 degrees (=) 44 degree temp rise is within specs. If you have any questions or concerns please feel free to contact us! Your LBA Technician, Tyler Rickard P.S. No payment was due for todays visit, it was covered with your membership. Have a great New Year!
Upon arrival I began the furnace tune up. First, I ran a static pressure test. Your system has a maximum rating of .5 static pressure. Your system is testing at .47 which is considered “high” but not failing. Next, I checked the running amps on the inducer and blower motor and both tested within manufacturer specifications. I took a temperature split on the system as well. The manufacturer wants it to be between 30 to 60 degrees. My tests shows the supply temp at 121 degrees (-) return temp of 76 degrees (=) 45 degree temp rise. If you have any questions or concerns please feel free to call us! Your LBA Technician, Tyler Rickard P.S. No payment was due for todays visit, it was covered with your membership. Have a great New Year!
Sold 2 star aorflow
Upon arrival I began the furnace tune up. First, I ran a static pressure test. This unit has a maximum static pressure of .5. When I tested your system is was testing at .7 in 1st stage heat and 1.4 in 2nd stage heat which is failing in both stages. Next, I did a test for any carbon monoxide leaks and my meter hit at 142ppm. I did a retest with my supervisors meter and it tested at 177ppm which is extremely unsafe to operate. Per EPA rules & regulations we are required by law to shut the furnace down and shut the gas to the furnace off, this way you don’t turn it on by accident and harm yourself or others in the home. Whenever we shut a furnace down, we add a “Red Tag” stating it is unsafe to operate. My Field Supervisor Jamie is here to find some different solutions for you. If you have any questions or concerns please feel free to call us! Your LBA Technician, Tyler Rickard P.S. No payment was due for todays visit. Also, customer decided to hold off on switching his membership until
Estimate for water heater
12/30/24 - Completed a full heating maintenance on all equipment. All filters were changed and proper operation was tested. Furnace 1 had a loud inducer motor, but the replacement was approved on site, so it is now running fine and it is not loud anymore. Overall, all other equipment was running well, it was in good condition, and there were no further issues found at this time.
Replaced inducer motor on furnace 1. Motor was cracked on the inside causing a loud noise. Put new motor in and system is functioning properly at this time
Went for a maintenance call today. Tested for static pressure, and system is passing. Did a carbon monoxide test, no co was detected when testing. Inspected heat exchanger no wear and tear. Did replace filter for customer. Temp split is passing for system. As well all electrical components for system are passing for manufacture specifications. Did notice blower wheel has a lot of dust built up. No further wear and tear on system. Thank you for choosing LBA services-Johann.
Happy call complete
Went for a furnace inspection today. Did a static pressure test, it passed. Did a carbon monoxide and gas leak test, no leaks. Inducer motor amperage passed. Gas pressure and pressure switch passed. Combustion analysis test passed. Temperature split between the supply and return duct passed. Blower motor amperage passed and blower wheel is clean. Filter got replaced. Thank you for choosing LBA services!
Dryer vent
S