Blue Springs, MO Residential HVAC & Plumbing Services
LBA Heating, Cooling, Plumbing & Electrical was started by people just like you who want and insist on high quality and reliable service. In Blue Springs, MO and throughout the Kansas City area, we treat each family and home as if it were our own. That includes rising to the challenge of being a Hero any time the need calls for extraordinary measures.
From routine maintenance to 24/7 emergency repairs, LBA Heating, Cooling, Plumbing & Electrical has you covered for all your home plumbing, heating, and air conditioning needs. The same goes for new and replacement system installations. Read our reviews and find out why your neighbors consider us to be their nearby heating and air company and local plumber in Blue Springs, MO.
Recent Jobs and Reviews in Blue Springs, MO
Blue Springs, MO at a glance
LBA Air Conditioning, Heating & Plumbing has completed 25 jobs in Blue Springs, MO in October 2024.
The most recent job was on October 29, 2024.
LBA Air Conditioning, Heating & Plumbing has completed 41 jobs in Blue Springs, MO in the last 12 months. The first job there was in February 2015.
Our Local Reviews by City
- Adrian, MO (2)
- Avondale, MO (1)
- Basehor, KS (24)
- Bates City, MO (1)
- Belton, MO (33)
- Blue Springs, MO (72)
- Bonner Springs, KS (30)
- Buckner, MO (1)
- Bucyrus, KS (6)
- Columbia, MO (1)
- De Soto, KS (25)
- Dearborn, MO (1)
- Edwardsville, KS (14)
- Eudora, KS (9)
- Fairway, KS (93)
- Freeman, MO (1)
- Gardner, KS (14)
- Gladstone, MO (65)
- Grain Valley, MO (58)
- Grandview, MO (75)
- Greenwood, MO (3)
- Holt, MO (3)
- Houston Lake, MO (7)
- Independence, MO (184)
- Kansas City, KS (427)
- Kansas City, MO (2902)
- Kearney, MO (3)
- Lake Lotawana, MO (4)
- Lake Quivira, KS (22)
- Lake Waukomis, MO (4)
- Lake Winnebago, MO (1)
- Lansing, KS (2)
- Lawrence, KS (19)
- Leavenworth, KS (8)
- Leawood, KS (429)
- Lee's Summit, MO (164)
- Lenexa, KS (608)
- Liberty, MO (116)
- Lone Jack, MO (1)
- Louisburg, KS (5)
- Merriam, KS (21)
- Mission, KS (204)
- Mission Hills, KS (78)
- North Kansas City, MO (10)
- Northmoor, MO (1)
- Oak Grove, MO (13)
- Odessa, MO (1)
- Olathe, KS (632)
- Ottawa, KS (1)
- Overland Park, KS (1458)
- Paola, KS (1)
- Parkville, MO (191)
- Peculiar, MO (1)
- Platte City, MO (13)
- Pleasant Hill, MO (1)
- Pleasant Valley, MO (4)
- Prairie Village, KS (527)
- Prairie Village New, KS (2)
- Raymore, MO (27)
- Raytown, MO (84)
- Riverside, MO (18)
- Roeland Park, KS (189)
- Shawnee, KS (1045)
- Shawnee Mission, KS (2)
- Smithville, MO (1)
- Spring Hill, KS (13)
- Stilwell, KS (66)
- Sugar Creek, MO (7)
- Weatherby Lake, MO (31)
- Wellsville, KS (1)
- Westwood, KS (30)
- Westwood Hills, KS (18)
Job Locations and Reviews
Arrived for furnace maintenance today. Ran static pressure test on system. System rating is .5 max, system is currently running at 1.0 which is double the manufacturer recommendations. This is causing system to over work and burn itself out. A filed supervisor was out to discuss options with you. There is a leak in the inducer motor and the condensate P trap. If this leaks enough it will cause electrical damage to furnace. I did a quick check on the ac also. It is a 2002 R-22 system. It is low on refrigerant, the compressor is over amping, and getting a very low temperature split. Options were presented today for repair but needs to talk over with wife. Thanks for choosing LBA.
Static decline
Completed furnace maintenance and inspection. I checked all components and amp draws. I tested airflow and temp splits. I cleaned up furnace and flame sensor. Furnace is running as it should. There is more dust inside the system than there should be so I recommended a filtration upgrade to stop that. Surge protection would be a great addition in protecting the system as well.
Spoke with Rose who was more than reluctant to hear my concerns today. I was able to explain that the ducts not passing a static pressure test doesn’t mean the equipment is bad or at fault. Some registers were found to be closed. After opening, static pressure numbers reduced to a more allowable .45 on max .5. Our conversation ended much better than it started. She’s happy with LBA Services. Just overwhelmed by life right now. She did cry and I listened. Though disarmed by the end, today was not a good sales opportunity.
Arrived to customer for furnace tuneup, and during the inspection we received a high-level call on static pressure. Other than that all components met within factory specs.
Done
Dead call
HC
HC
HC
HC
Arrived to do a performance maintenance. Set up for combustion analysis and static pressure tests. Verified operation of all mechanical and electronic components in the furnace. Cleaned the flame sensor and retested its performance. Checked blower for cleanliness and to see if there is any play in the bearings. Found that the fan for both heating and cooling is heavily coated in dust debris. Checked systems heat exchanger to ensure proper venting of flue gas. Checked for carbon monoxide in the air stream. Spoke with homeowner about the system. Furnace is operational at this time.
Arrived to customers for AC & Furnace tuneup and during the inspection we discovered the Humidifier wasn’t operating along with dirty blower wheel. Other than that all other components and refrigerant levels are within factory specs.
Static decline
Arrived to remedy a leaking humidifier. Turned system on and found the leak on the solenoid valve. The water pressure would push the hose off of the barbed fitting. Cut the loose end of the hose off and pushed it all the way down on the barbed fitting. Fastened a zip tie on the hose over the barbed fitting to help ensure the humidifier won’t leak in this place again. Tested system operations. Furnace and humidifier are operating properly at this time.
Customer called stating furnace was not heating. It was found on initial inspection that furnace safeties were not plugged together and hence not being a complete circuit. Plugged harness together and restarted furnace and it ignited. System operating normally upon departure.
Completed warranty form
.
.
10/11/24 - Completed a full heating maintenance on four RTU’s. Filters were changed and proper operation was tested. Overall, all units were in good condition, they were all running well, and there were no issues found at this time.
Checking on water pressure after hvac visit
Went for a maintenance call today. When going to furnace tested for static pressure. System rated for .8. System is operating at .6 passing for manufacture specifications. Did replace filter for customer. Did CO readings no CO was detected. Heat exchanger is in tact no sign of wear. Did notice the blower motor is getting dust. Cleaned out flame sensor and pressure switch hose. All electrical components are passing for manufacture specifications. Temp split is passing for furnace. Did notice water panel need to be replaced sent estimates to customer. System is up and running before leaving. Thank you for choosing LBA services.
Went for a maintenance call today. When going to furnace did change out filter for customer. Tested for static pressure. System rated for .5. System operating at .4 passing for manufacture specifications. When looking a heat exchanger all in tact no wear and tear on furnace. No CO was detected when doing CO readings. Temp split for system is passing. Cleaned out pressure switch port and flame sensor. All electrical components are passing for manufacture specifications on furnace. Replaced batteries for thermostat as requested from customer. Did notice water panel needs to be replaced for humidifier. Will send estimates via mail. System up and running before leaving thank you for choosing LBA services-Johann.
Standard bypass humidifier
Na