Blue Springs, MO Residential HVAC & Plumbing Services
LBA Heating, Cooling, Plumbing & Electrical was started by people just like you who want and insist on high quality and reliable service. In Blue Springs, MO and throughout the Kansas City area, we treat each family and home as if it were our own. That includes rising to the challenge of being a Hero any time the need calls for extraordinary measures.
From routine maintenance to 24/7 emergency repairs, LBA Heating, Cooling, Plumbing & Electrical has you covered for all your home plumbing, heating, and air conditioning needs. The same goes for new and replacement system installations. Read our reviews and find out why your neighbors consider us to be their nearby heating and air company and local plumber in Blue Springs, MO.
Recent Jobs and Reviews in Blue Springs, MO
Blue Springs, MO at a glance
LBA Air Conditioning, Heating & Plumbing has completed 25 jobs in Blue Springs, MO between November 2024 and December 2024.
The most recent job was on December 2, 2024.
LBA Air Conditioning, Heating & Plumbing has completed 41 jobs in Blue Springs, MO in the last 12 months. The first job there was in February 2015.
Our Local Reviews by City
- Adrian, MO (2)
- Avondale, MO (1)
- Basehor, KS (24)
- Bates City, MO (1)
- Belton, MO (33)
- Blue Springs, MO (72)
- Bonner Springs, KS (30)
- Buckner, MO (1)
- Bucyrus, KS (6)
- Columbia, MO (1)
- De Soto, KS (25)
- Dearborn, MO (1)
- Edwardsville, KS (14)
- Eudora, KS (9)
- Fairway, KS (93)
- Freeman, MO (1)
- Gardner, KS (14)
- Gladstone, MO (65)
- Grain Valley, MO (58)
- Grandview, MO (75)
- Greenwood, MO (3)
- Holt, MO (3)
- Houston Lake, MO (7)
- Independence, MO (184)
- Kansas City, KS (427)
- Kansas City, MO (2902)
- Kearney, MO (3)
- Lake Lotawana, MO (4)
- Lake Quivira, KS (22)
- Lake Waukomis, MO (4)
- Lake Winnebago, MO (1)
- Lansing, KS (2)
- Lawrence, KS (19)
- Leavenworth, KS (8)
- Leawood, KS (429)
- Lee's Summit, MO (164)
- Lenexa, KS (608)
- Liberty, MO (116)
- Lone Jack, MO (1)
- Louisburg, KS (5)
- Merriam, KS (21)
- Mission, KS (204)
- Mission Hills, KS (78)
- North Kansas City, MO (10)
- Northmoor, MO (1)
- Oak Grove, MO (13)
- Odessa, MO (1)
- Olathe, KS (632)
- Ottawa, KS (1)
- Overland Park, KS (1458)
- Paola, KS (1)
- Parkville, MO (191)
- Peculiar, MO (1)
- Platte City, MO (13)
- Pleasant Hill, MO (1)
- Pleasant Valley, MO (4)
- Prairie Village, KS (527)
- Prairie Village New, KS (2)
- Raymore, MO (27)
- Raytown, MO (84)
- Riverside, MO (18)
- Roeland Park, KS (189)
- Shawnee, KS (1045)
- Shawnee Mission, KS (2)
- Smithville, MO (1)
- Spring Hill, KS (13)
- Stilwell, KS (66)
- Sugar Creek, MO (7)
- Weatherby Lake, MO (31)
- Wellsville, KS (1)
- Westwood, KS (30)
- Westwood Hills, KS (18)
Job Locations and Reviews
S
Power switch was off
Went for a maintenance call today. When going to furnace test for static pressure. Static is passing for system. Did a co test, no was detected when testing. Inspected heat exchanger no wear and tear. All electrical components are passing for system. Temp split is passing all well. No further wear and tear. Thank you for choosing LBA services-Johann.
Uninstalled furnace and coil. Raised furnace and coil to help with static pressure. Static pressure is now .5 for both a/c and furnace
Install new Furnace Model FR801T1005A21UHSNA, new basic thermostat & 1* Duct Modifications. 2 Year Labor Warranty 10 Year Parts Warranty Limited Lifetime Heat Exchagner Warranty
80% furnace and 1 star ductwork
Upon arrival I began the furnace tune up. This is a 2017 Champion Furnace with Champion AC/Coil to match. First, I did a static pressure test. This system is rated for a maximum static pressure of .5. When I tested your system in was testing at .8 which is failed above the max allowed. The homeowner also advised me that each time the system shuts down it makes a loud popping noise which is from the duct work having too much pressure from the static. My Field Supervisor Caden is here to find a solution to the static pressure. Next, I did a CO test. My CO meter picked up on 98ppm(parts per million) which is unsafe. Any amount of CO is dangerous but these reading are awfully high. Per EPA Rules & Regulations I am required to shut the gas valve to the furnace to the OFF position so that even if the thermostat calls for heat, the furnace will not light. Caden is looking up all the options for the homeowner. I am waiving todays trip and diagnosis fee because the homeowner will have to make s
Came out here for a heating tuneup upon arrival tested static static was passing fairly new unit. Everything was looking good replace filter for them ensure that every operation within the heating cycle is working perfectly fine and amps on the inducer and the blower motor were good. Cleaned out flame sensor. Thank you for choosing LBA - Ramon.
Working on resolution
Sold 2 star airflow with duct seal
Arrived to do a performance maintenance. Set up for combustion analysis temperature split and static pressure tests. Found that the system is passing the static pressure test but is causing the system to overheat. Reached out to a field supervisor to help find a balance between the static pressure and the heat generated by the furnace. Verified operation of all mechanical and electronic components of the furnace. Cleaned the flame sensor and retested its performance. Checked blower for cleanliness and to see if there is any play in the bearings. Checked systems heat exchanger to ensure proper venting of flue gas. Found premature wear on present on the heat exchanger. With field supervisor increased the fan speed for heating to protect the heat exchanger from overheating but now the system is failing the static pressure test. Field supervisor took over the diagnosis on the systems static pressure. Furnace is operational at this time.
Went for a maintenance call today. When going to furnace tested for static pressure. Static is passing when testing. Did a co test no co was detected when testing. Inspected heat exchanger no cracks were detected. All electrical components are passing for manufacture specifications. Temp split is passing as well. Blower wheel, drain line, flame sensor, and pressure switch hose are clean. No further wear and tear. Thank you for choosing LBA services.
Completed full heating maintenance.
95% furnace w/ single stage heating and multi speed fan motor *10 year parts warranty *1 year labor warranty
Working on 2* airflow bid
No on Site work. Called customer to follow up from quotes given last week. Left voicemail.
Arrive to customers for a furnace tuneup in during the inspection, receive the high call static pressure. All other components met within factory specs
Went for a service call. When going to furnace, the furnace wouldn’t turn on. Tested transformer received voltage for 120 and 24 volts. Thermostat was getting correct 24 volts for call. Ac worked when calling. Heat was not working. System has a bad control board. No further work was done for today. Customer would like to order part and replace.
Follow Up - Call
Presented two solutions for the airflow imbalance in this home. He is wanting to chew on this for the moment. Appreciates the info. I’d like another shot at this with Vitti to be available as well.
Arrive to customers for the furnace tuneup, and during the inspection we received a high call on static pressure along with discovering a dusty Blower wheel. All other components met the factory specs.
Must replace furnace
Went for a furnace maintenance today. did a static pressure test, it passed. Did a carbon monoxide leak test, there is a leak. After inspecting the heat exchanger, I found a crack. The furnace is red tagged and gas is shut off to the furnace only. Thank you for choosing LBA services!
Customer called stating system was not heating. Customer noted they did not hear anything happening when they set the thermostat to heat. Found inducer motor extremely hot and over amping. Pulled inducer and found bird stuck in impeller wheel. Pulled bird and reinstalled inducer and cycled power. Furnace began heat sequence and lit, ran in test mode for several minutes to ensure operation. System running normally upon departure.
Completed inspection. Adam is working with homeowner to sell what was recommended. Has a follow up call for expansion tank and PRV. Closing out.