HVAC & Plumbing Services For Your Lenexa, KS Home That Are Simply Perfect
Are you having problems with your home in Lenexa, or looking to replace some old pieces of your home with something updated and new? If you need some help in the areas of plumbing, heating, or air conditioning, give your hometown LBA heroes a call. We’ll come to you, fix what is broken or help you get the very best in new fixtures or appliances for your home, and stay until you’re satisfied with the job we’ve done.
Lenexa Heating Repair
When your heater breaks down in Kansas in the middle of winter, you need someone to fix it for you fast. Otherwise, you and your pipes might freeze in the dead of winter! We promise that we will get to you as soon as possible, figure out why your heater isn’t working, and help you get warm again as soon as possible.
In addition to heating repair, we provide other heating services in Lenexa, too. We would be happy to tune your heater up in the fall, before you turn it on, and to perform any maintenance that it requires. We’ll also help you find the perfect new heater for your family, whether it’s just time to replace it or yours has worn out.
Lenexa A/C Repair
We provide similar services for air conditioners. Whether you need yours repaired, replaced, or tuned up, we’ll get the job done so you can get back to your normal life. We know that you do your best to live a life you love and that you can’t engage in that life as well when your home isn’t working. That’s why we’ll go out of our way to get things functioning well again fast.
Lenexa Plumber
Maybe you’re struggling with plumbing instead of heating and air conditioning. We can help you there, too! We’ll fix your plumbing problem, whether it’s as simple as clearing a clogged drain or as complex as repiping your home or repairing your sewer. Our experienced plumbers are ready and waiting to help you out.
Need advice about fixtures or plumbing appliances to put in your house? We can help you with that, too. We know who makes the faucets, sinks, tubs, garbage disposals, toilets, and water heaters that we trust the most, and we’ll help you get the very best for your money.
Lenexa Drain Cleaning
One of our most popular plumbing services is drain cleaning. We’ll clean out your plugged drains, whether they’re under your sink, behind your wall, or in your sewer. Our skilled plumbers will make sure everything is flowing just the way you need it to before they leave. We’ll also do whatever we can to make sure the problem doesn’t happen again.
A home HVAC system should be serviced twice a year in Lenexa, KS, once before the summer and once before the winter. Having your HVAC unit serviced often will help it last longer and run more efficiently during the more intense heating and cooling seasons. Regular maintenance also ensures that you are aware of any potential problems your HVAC system is experiencing before it becomes a major repair or system failure. To find out more about getting your home HVAC system serviced, call us today.
Some signs of a burst pipe include:
- Your water pressure has decreased.
- You notice random drips or puddles of water.
- Your water looks or smells strange.
Another sign you might have a burst pipe is if your water bill has drastically increased. If you suspect that you have a burst pipe in your home, you should have it inspected by a plumber right away to prevent it from causing further damage to your home. Contact us today to get your burst pipe repaired.
The following are considered plumbing emergencies in Lenexa, KS:
- A burst, frozen or leaking pipe.
- A gas leak in your home.
- Multiple clogged drains or toilets.
If you notice any of the issues above, you should contact a plumber immediately to get the issue resolved. Plumbing emergencies can vary, but you can be sure that you have a plumbing emergency if your issue poses a risk to your health or your home. To get help with your plumbing emergency, give us a call today.
Discover The LBA Difference With These Customer Reviews!
Still wondering if LBA Heating, Cooling, Plumbing & Electrical is the right company to call? Don't just listen to us, listen to our fans! Check out our customer reviews below to find out what makes LBA Heating, Cooling, Plumbing & Electrical the most trusted plumbing and HVAC provider in Lenexa!
Recent Jobs and Reviews in Lenexa, KS
Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction with the service provided. Customers consistently express appreciation for the professionalism, efficiency, and expertise demonstrated by the technicians. Recurring themes include prompt and timely service, with many reviewers highlighting how quickly issues were diagnosed and resolved. The technicians are frequently praised for being friendly, courteous, and communicative, taking the time to thoroughly explain problems and solutions in clear, understandable terms. Many customers specifically mention feeling confident that they were not being upsold unnecessary services, which they found refreshing and trustworthy. The quality of workmanship receives high marks, with reviewers noting thorough inspections, attention to detail, and jobs completed efficiently—often within hours. Several customers express gratitude for cost-effective solutions and fair pricing, with some noting significant savings compared to other estimates. The membership and maintenance programs are highlighted as providing excellent value and peace of mind. Overall, the tone is enthusiastic and appreciative, with many reviewers stating they would highly recommend the service to others and plan to use the company again in the future. The sentiment reflects a customer base that feels well-served, respected, and confident in the technical abilities and integrity of the service providers.
Lenexa, KS at a glance
LBA Air Conditioning, Heating & Plumbing has completed 25 jobs in Lenexa, KS in November 2025.
The 25 customer reviews shown here average 5.0 out of 5.
The most recent job was on November 18, 2025.
LBA Air Conditioning, Heating & Plumbing has completed 92 jobs in Lenexa, KS in the last 12 months. The first job there was in December 2014.
Our Local Reviews by City
- Adrian, MO (2)
- Avondale, MO (1)
- Basehor, KS (24)
- Bates City, MO (1)
- Belton, MO (33)
- Blue Springs, MO (72)
- Bonner Springs, KS (30)
- Buckner, MO (1)
- Bucyrus, KS (6)
- Columbia, MO (1)
- De Soto, KS (25)
- Dearborn, MO (1)
- Edwardsville, KS (14)
- Eudora, KS (9)
- Fairway, KS (93)
- Freeman, MO (1)
- Gardner, KS (14)
- Gladstone, MO (65)
- Grain Valley, MO (58)
- Grandview, MO (75)
- Greenwood, MO (3)
- Holt, MO (3)
- Houston Lake, MO (7)
- Independence, MO (184)
- Kansas City, KS (427)
- Kansas City, MO (2902)
- Kearney, MO (3)
- Lake Lotawana, MO (4)
- Lake Quivira, KS (22)
- Lake Waukomis, MO (4)
- Lake Winnebago, MO (1)
- Lansing, KS (2)
- Lawrence, KS (19)
- Leavenworth, KS (8)
- Leawood, KS (429)
- Lee's Summit, MO (164)
- Lenexa, KS (608)
- Liberty, MO (116)
- Lone Jack, MO (1)
- Louisburg, KS (5)
- Merriam, KS (21)
- Mission, KS (204)
- Mission Hills, KS (78)
- North Kansas City, MO (10)
- Northmoor, MO (1)
- Oak Grove, MO (13)
- Odessa, MO (1)
- Olathe, KS (632)
- Ottawa, KS (1)
- Overland Park, KS (1458)
- Paola, KS (1)
- Parkville, MO (191)
- Peculiar, MO (1)
- Platte City, MO (13)
- Pleasant Hill, MO (1)
- Pleasant Valley, MO (4)
- Prairie Village, KS (527)
- Prairie Village New, KS (2)
- Raymore, MO (27)
- Raytown, MO (84)
- Riverside, MO (18)
- Roeland Park, KS (189)
- Shawnee, KS (1045)
- Shawnee Mission, KS (2)
- Smithville, MO (1)
- Spring Hill, KS (13)
- Stilwell, KS (66)
- Sugar Creek, MO (7)
- Weatherby Lake, MO (31)
- Wellsville, KS (1)
- Westwood, KS (30)
- Westwood Hills, KS (18)
Job Locations and Reviews
LBA will bill JCWW upon job completion, per pre-approval through JCWW
11-18-25 Classroom EG32 computer Lab2 and the server room AC system has frozen up. Found the blower wheel on the carrier furnace has blown apart and the motor is extremely hot Carrier serial 1201A12388 Ordered and picked up new blower wheel and 3/4 Hp blower motor with run capacitor. The OEM blower motor was not available in any of this stores locally and was also at least a week out. So we installed a non-OEM motor. This was my decision. Install all the new blower wheel and motor check for proper rotation and operation. System is working at this time.
Went for a maintenance call today for heat. Tested for static pressure system is passing when in heat. All electrical components are passing for manufacture specifications. Did a combustion test is within range. Inspected heat exchanger no cracks/leaks were detected. Checked temp split and is passing. Cleaned flame sensor and pressure switch hose. Did notice biological growth in evaporator coil pan. Will recommend for a UV light to help prevent more growth. System is up and running before departure. Thank you for choosing LBA services-Johann
Went for a heat inspection on system. When inspecting heat exchanger did find heat stress and rust on eyelids as well for a crack on the heat exchanger. Did a combustion test and verified the cracked. Will red tag system and will not recommend to have on until heat exchanger replaced. Thank you for choosing LBA services-Johann
11/13/25 - Completed a full heating maintenance on two RTU’s. The filters were changed, the heat exchangers were checked, and proper operation was tested. Overall, both units were in good condition and they were both running well. The only issue found is that the larger carrier RTU has a worn AX49 belt that is also starting to crack, so it will need to be replaced.
Down stair bathroom was cleared before I arrived. Upstairs master bathroom cleared drain. Reccomended pop up assembly with bigger tailpiece if issue is reoccurring
I ran the system in heat and it trip the high limit. I check all components from the broad and everything was receiving the proper volts for everything to run. I found that the blower motor was not working. I tested for voltage at the blower motor and it was received the right voltage. This said the blower motor has failed in this unit and needs to be replaced. I sent info to Rick to email quote to Doug to be approved.
During maintenance today it was discovered that the blower motor capacitor in the west unit heater was underperforming. This capacitor was replaced with a new and tested capacitor. Thank you, Jon
Resent estimate to customer
Today heating maintenance was performed on two unit heaters and two rooftop units. The west unit heater was not operating when I arrived. This was corrected by cleaning the flame sensor which is part of the unit heater maintenance process. This unit also has an underperforming capacitor. Verbal approval was granted for it’s replacement that will occur today. Both rooftop units have a major deficiency with the east unit having multiple components that are recommended to be addressed. These were documented and forwarded for repair quotes. All filters were replaced today and checklists for the maintenance were completed. Thank you, Jon
Took pictures of the replaced heat exchanger in service titan customer request
Today I did a full heating maintenance on 2 furnaces and 4 unit heaters. changed all filter took amp draws off all working components and took temp splits at this time all units are running as should. The southwest unit heating had to relight the pilot lite. And now it is running as should.
*)*(*)*)*)*)*)**(&(*))**(*()*)*) Parts delayed by Lennox will be shipped to shop11/11/25 *)*)*)*’gmggjgjgjjgjg*(&(*(*(*(*gh**g(gh Joe, During heating maintenance this year there were multiple units that have deficiencies. Below is a time plus material estimate for their correction. The time to source, pick up parts and perform the repairs is estimated to be between 6-8 hrs at a rate of $139 per hour. The materials for these repairs total $1,744.17. The time used to complete the repairs will be added to the material cost at the completion of the repairs. The gas valves listed below will more than likely be used however if (very small chance) there is an obstruction in the gas manifold in the units that is discovered when disassembled it will be cleared and the valve/s may not be used depending on need and subtracted from the material cost. An itemized list of material cost is listed below. Thank you, Jon ———————————————————————————————— Material cost listing p
Found a leaf blocking the burner from receiving gas so the flame would not reach the flame sensor. Pulled out the leaf and system ran as it should.
Returned to replace flame sensor. Installed new flame sensor. Also cleaned condensation cup. Cycled tankless few times and tankless fired up each time.
Today the system that serves the showroom was confirmed as having a second stage control circuit failure. The circuit was traced inside the rooftop unit and to the thermostat. I discovered that the thermostat wire that serves the second stage heat was tripping the transformer safety. This was confirmed by operating the system on second stage without the wire in place. A delay timer was installed to serve as the 2nd stage heat thermostat wire and was set on a ten minute delay. The system was operated after the rewire and is functioning properly. The thermostat programming was changed to single stage heating and the second stage heat thermostat wire was removed. It does now cycle between 1st stage and second stage heating via the newly installed delay. Thank you, Jon Tech notes: Trane s/n 22051492JA
Completed furnace, maintenance and inspection. I cleaned flame sensor, spark igniter, and wiped down the furnace. I checked amp drawers and components. I tested airflow and temp splits. I changed our air filter and humidifier pad with customer provided filter and pad. I tested for carbon monoxide and inspected heat exchanger. Furnace is operating within manufacture specifications at departure.
Returned to perform previous proposed work. Customer wants me to look at her toilets. They seem to run when they shouldn’t. Discovered that all fill valves are overflowing into flush valve. This can be caused by high water pressure. Main floor toilet is the one having the most issues with fill valve. Recommended replacing fill valve. Customer had me look in basement bathroom and found additional water leak. Also found expansion tank to be have failed as well. After thorough discussion with customer about repairs, customer decided to move forward with water line repairs above basement bathroom ceiling and replace fill valve in main floor toilet. Will replace expansion under workmanship warranty. Expansion tank was not properly supported and was not pressured to house pressure causing it to prematurely fail. Went ahead and started by replacing main entrance valve, new prv, and added boiler drain. Also replaced expansion tank and set tank to 75psi to match new house pressure. Set prv to 7
Quote to replace the heat exchanger and the inducer motor mounting bushings on the York package unit serial N1G3956095. The heat exchanger is rusted through at the seams. The inducer motor mounting bushings are missing from a previous inducer motor replacement. Price includes the factory replacement parts and labor. Repairs covered by a one year parts and labor warranty. The parts are currently in stock locally and the repairs can be made as soon as possible with the approval of this quote. Note: the inducer motor and wheel will have to be removed to replace the missing bushings. There is a risk of the mounting studs and or the wheel being damaged during removal. If these parts are damaged and not reusable these repairs will be quoted separately.
Completed furnace, maintenance and inspection. I checked amp draws and tested components. I tested airflow and temp splits. I cleaned flame sensor and wiped down furnace. Furnace is operating within manufacture specifications. The humidifier had overflowed water down onto the furnace, so I turned down the amount of water coming through to avoid the humidifier from ruining components in the furnace. I checked out the components that the water had dripped by and the components were fine.
Today I tested system #2 for the front portion of the building. I found the system was cutting out on low pressure and not allowing it to run correctly. I took the pressure and found this system has lost nearly all of its R22. Due to the age of this equipment and not warranted after working on a R22 system. At this time I have sent Rick information for replacement
*(*)*)*))*)*)*)*)*)*)*))*)*)*)*’ 3hrs labor includes diagnostics, sourcing parts and writing estimate *)*)*)&)&)&)&)*)*)&))&*))*)*)**)*)*)*)*)*)*)*)*)*))*)*)*)*))* Today I arrived and accessed the roof. There were 3 rooftop units that did not function during the heating maintenance performed on the 30th of October. Units #5, 8 and 10 were diagnosed. Unit’s #4 and 7 were confirmed to have stretched belts that have worn into their pulleys and have been slipping. Unit#5 (s/n ending 00846) has a blower contactor that has failed. The 24v control voltage was off on an internal fuse. The motor wires are scorched at the contactor. A new contactor and minor wire repair is recommended and the restore operation of this unit. Unit#8 (s/n 00847). This unit is following it’s ignition cycle however when the gas valve receives proper voltage from the control board it is not allowing gas through to the orifices. Unit#10 (s/n 00783) This unit is presenting the same symptoms as
Today I did a full heating maintenance I changed all filters took amp draws off all working components took temp splits in my return and supply’s… I did find today on unit ending in serial number 92JA Stage 2 heating trips transformer need further diagnostics. All other units working as should at this time.
Customer called in about disposal making loud noises. Upon arrival, turned disposal on and made clanking noises. Looked inside disposal and disposal is rusting out and there’s a hole on side of disposal. Informed customer we need to replace disposal. Gave customer several estimates and customer opted for 3/4HP Disposal. Removed and disposed of old disposal. Installed new insinkerator 3/4HP Disposal. Also installed new tubular p trap and replaced disposal collar as well. Checked for leaks and no leaks detected. 1 year parts and labor warranty. 10 year manufacture warranty
11-5-25 Classroom W116 has no heat Patrick and I checked out the unit found that the thermostat is failed and installed a new thermostat cycled the system is working at this time. Classroom W125 has no heat. Set the thermostat for heat, we got up on the roof and found the RTU unit was running in both AC and heat. However, the burns were not coming on. First thing I did was check the heating system. I found a spider web in the burner orifice. Remove the the web tested the burner system upon the roof. System is working properly there. We then tested the thermostat by isolating the system from the thermostat and we found that the thermostat is the problem bringing an AC and heat on at the same time. They are gonna pick it up and install new thermostat. For now what I did was I disconnected the Y1 wire at the RTU so the AC does not run once they replace the thermostat they’ll reconnect that wire.
Very, very informative. Liked being given options. Very professional.
Fine.
Both gentlemen were very appreciative, communicative, informative, and advised well. I am very a little more cognitive of the small issues and be able to consider them going forward. Thank you.
Both gentlemen were very appreciative, communicative, informative, and advised well. I am very a little more cognitive of the small issues and be able to consider them going forward. Thank you.
Very good young man working for LBA.
Scott arrived quickly to fix our emergency plumbing problem on a holiday. He was professional, and got the job done in record time. We will definitely be using your company for future needs, and will request Scott.
On time and efficient.
As much as we hate having to spend money on home maintenance, he made the experience good.
Excellent Service
Professional and explained entire process
TJ Mays came out to service my Hot Water Heater today because the pilot light wasn't working. He replace the connection to the pilot light and did a couple of things. He was very good, knowledgeable, communicate very well, had stamina to get it done, and was very congenial. I would recommend him.
Jason was great! Diagnosed and fixed my faulty toilet installation quickly.
LBA Services today performed an Air Conditioner Unit Replacement installation, Duct Cleaning/Dryer Vent Cleaning up through the attic and roof, installed additional Output Duct Flows & Ceiling Vents from the Furnace Unit, Clean the Furnace Fan, and replace the A-Coil. These processes were all performed by Joe Kile, Edmund Semple, and Reece Middleton - and the 3 of them performed the work in a co-ordinated manner, excellent communication between themselves, very informative with me as I observed, very knowledgeable, experienced, and efficient. And also very congenital. I would recommend LBA Services and these gentlemen to anyone. Thanks to all three for their hard work. Paul M. Odle
Lindsey was very detail oriented, informative, communicative, described scope of issue well, options, and very congenial. I would recommend her to anyone.
Ren Wallace was very thorough, informative, communicated very well, insured my understanding, and very knowledgeable, etc. I would recommend her to my neighbors and others if asked.
Excellent communication
Patrick Was Great!
Chase was very thorough in explaining the vent cleaning process. We will definitely be using LBA for future HVAC needs.
The LBA crew just finished our total replacement with new heating, a/c and duct cleaning. Cannot say enough how pleased I (we, my family) am/are with the knowledgeable techs, Scott our advisor and the install crew today. Thanks so much! Also, the unexpected touch of providing space heaters the last 2 evenings was extremely appreciated. You've got a new lifelong client
When I get exemplary service that goes above and beyond, I always like to share with y'all. Contacted a handful of local firms, some showed, couple just had crazy schedules. Tues am their tech arrived and listened to the symptoms I've been dealing with the last summer and winter, diagnosed what I had a feeling was the problem since this Heil system started faltering. Long story short, holes in the heat exchanger which meant system was down for good. For people who don't understand, you cannot run a heater with bad exchanger as that is potentially deadly, meaning we were living pioneer style lol. Pricing was considerate, not blue sky but not cheapest in town, included several extras we desperately needed. The post I made to LBA Air Conditioning, Heating & Plumbing : Your crew just finished our total replacement with new heating, a/c and duct cleaning. Cannot say enough how pleased I (we, my family) am/are with the knowledgeable techs that found the problems, Scott our advisor and the install crew today. Thanks so much! Also, the unexpected touch of providing space heaters the last 2 evenings was extremely appreciated. You've got a new lifelong client
As always with LBA, Tech David Wilson was prompt, professional and very informative.
David was great. He checked the water flow throughout the house after turning the water back on. He explained how to change the filter on the sediment filtration system.
Excellent service.
2024 Duct Work
Excellent service