Leawood, KS Residential HVAC & Plumbing Services
LBA Heating, Cooling, Plumbing & Electrical was started by people just like you who want and insist on high quality and reliable service. In Leawood, KS and throughout the Kansas City area, we treat each family and home as if it were our own. That includes rising to the challenge of being a Hero any time the need calls for extraordinary measures.
From routine maintenance to 24/7 emergency repairs, LBA Heating, Cooling, Plumbing & Electrical has you covered for all your home plumbing, heating, and air conditioning needs. The same goes for new and replacement system installations. Read our reviews and find out why your neighbors consider us to be their nearby heating and air company and local plumber in Leawood, KS.
Recent Jobs and Reviews in Leawood, KS
Leawood, KS at a glance
LBA Air Conditioning, Heating & Plumbing has completed 25 jobs in Leawood, KS in October 2024.
The most recent job was on October 28, 2024.
LBA Air Conditioning, Heating & Plumbing has completed 66 jobs in Leawood, KS in the last 12 months. The first job there was in December 2014.
Our Local Reviews by City
- Adrian, MO (2)
- Avondale, MO (1)
- Basehor, KS (24)
- Bates City, MO (1)
- Belton, MO (33)
- Blue Springs, MO (72)
- Bonner Springs, KS (30)
- Buckner, MO (1)
- Bucyrus, KS (6)
- Columbia, MO (1)
- De Soto, KS (25)
- Dearborn, MO (1)
- Edwardsville, KS (14)
- Eudora, KS (9)
- Fairway, KS (93)
- Freeman, MO (1)
- Gardner, KS (14)
- Gladstone, MO (65)
- Grain Valley, MO (58)
- Grandview, MO (75)
- Greenwood, MO (3)
- Holt, MO (3)
- Houston Lake, MO (7)
- Independence, MO (184)
- Kansas City, KS (427)
- Kansas City, MO (2902)
- Kearney, MO (3)
- Lake Lotawana, MO (4)
- Lake Quivira, KS (22)
- Lake Waukomis, MO (4)
- Lake Winnebago, MO (1)
- Lansing, KS (2)
- Lawrence, KS (19)
- Leavenworth, KS (8)
- Leawood, KS (429)
- Lee's Summit, MO (164)
- Lenexa, KS (608)
- Liberty, MO (116)
- Lone Jack, MO (1)
- Louisburg, KS (5)
- Merriam, KS (21)
- Mission, KS (204)
- Mission Hills, KS (78)
- North Kansas City, MO (10)
- Northmoor, MO (1)
- Oak Grove, MO (13)
- Odessa, MO (1)
- Olathe, KS (632)
- Ottawa, KS (1)
- Overland Park, KS (1458)
- Paola, KS (1)
- Parkville, MO (191)
- Peculiar, MO (1)
- Platte City, MO (13)
- Pleasant Hill, MO (1)
- Pleasant Valley, MO (4)
- Prairie Village, KS (527)
- Prairie Village New, KS (2)
- Raymore, MO (27)
- Raytown, MO (84)
- Riverside, MO (18)
- Roeland Park, KS (189)
- Shawnee, KS (1045)
- Shawnee Mission, KS (2)
- Smithville, MO (1)
- Spring Hill, KS (13)
- Stilwell, KS (66)
- Sugar Creek, MO (7)
- Weatherby Lake, MO (31)
- Wellsville, KS (1)
- Westwood, KS (30)
- Westwood Hills, KS (18)
Job Locations and Reviews
Arrived to do a performance maintenance. Set up for combustion analysis and static pressure tests. Verified operation of all mechanical and electronic components in the furnace. Found that the inducer is leaking condensation from the exhaust vent. Cleaned the flame sensor and retested its performance. Checked blower for cleanliness and to see if there is any play in the bearings. Found that the blower wheel is coated in dust buildup. Checked systems heat exchanger to ensure proper venting of flue gas. Checked for carbon monoxide in the air stream. Performed an electronic gas leak search. Spoke with homeowner about the system. With homeowners approval ordered the new inducer and went to pick it up. Returned and removed the old inducer. Cleaned the mounting surface to ensure a good seal. Installed a new gasket between the inducer and collector box. Mounted the new inducer and plumbed it to the pressure switches. Ran system monitoring the systems exhaust gas to ensure the system is still
Presented replacement options based on age. She chose to repair inducer. Heat xc and blower are good. Static is excellent.
Went for a maintenance call today for furnace. When testing static pressure. System is at max rating for system. Tested for CO reading was 0ppm passing. Did notice heat exchanger had stress marks and some rust forming. Showed customer when inspecting heat exchanger. Blower wheel is clean. Did clean out flame sensor, drain line, and pressure switch hose. All electrical components are passing for manufacture specifications. System is up and running before leaving. Renewed membership with customer. No further wear and tear. Thank you for choosing LBA services-Johann.
X
Completed furnace inspection for customer. System tested within manufacturer specifications aside from higher than usual carbon monoxide readings, checked furnace with inspection camera and found light surface rust, some signs of heat stress and possible crack in heat exchanger, furnace was tagged.
work
X
Completed furnace inspection for customer. There were items of concern we brought to the attention of the customer. It was found that system was leaking carbon monoxide, upon visual inspection it was found that system had a failed gasket that was casing carbon monoxide and water to leak internally inside furnace as well as inducer motor housing being cracked and leaking as well. Turned over to field supervisor for further advisement to the customer.
10-24-24 The dining room air handler on the upper floor, mechanical room AHU#4 Blower wheel is running very loud and vibrating the unit. I found the staff on the opposite side of the blower motor. The bearing collar has dug into the shaft and is basically flopping around. That’s where the noise coming from. This air handler is dated 1989 I have a call in to the York manufacturer to find out about OEM parts. it may be difficult to modify the shaft 3” and taper down to 1-1/2”, so OEM is probably the best way to go with this. if we can even be modified, I’m waiting on them to call me back. I do have pictures on my phone if needed I do have. I did send pictures to CFM pricing and availability.$&
X
Went for a furnace maintenance. Tested for static pressure for furnace system is passing for static. Did CO reading for system. No CO was detected at this time. All electrical components are passing for manufacture specifications. Cleaned out drain line and pressure switch hose. As well as the flame sensor. Temp split for system is passing. Did notice the system had biological growth forming. Showed customer when cleaning out drain line. Supervisor will have solutions. And will have estimates sent to customer.
Arrived for multi system furnace maintenance. Systems are only 1 year old. On both systems all electrical components are running properly. I checked static on both. Both systems are as good as they will be. 0 ppm carbon on both systems. Blower wheels will need to be cleaned. Foundation work was done recently and the wheels collected a lot dust from it. Combustion analysis on both systems showed they are burning fuel properly. Both systems are running good at this time. Thanks for choosing LBA.
And for a furnace maintenance today. Started off with a static pressure test, it passed. Changed the filter due to the old one being dirty. Did a carbon monoxide leak test with my meter, There was no leaks temperature split between the supply and return duct passed. heat exchanger was in ideal condition. Gas pressure, med factory specifications. Pressure switch past the capacitor for the inducer motor passed. Blower wheel was dirty butt blower motor amperage passed. Thank you for choosing LBA services!
.
Called and spoke with Gordon about options that I presented last week. Still thinking about them, and will get back to us when they make a decision.
10-9-24 AHU# 8 and #3 blowers are not coming on. Found all of the air handlers on the top floor are not running. John and I checked the alarm panel a kid last night activated one of the stations on the floor. We did find the panel. The system was in alarm. We reset panel. All the blowers came on All the air handlers on the upper floor are running at this time.
Clean and seal
10-8-24 Men’s Steam room generator is not working. Found the Mr Steam unit locked out on the high water safety. I removed the high water safety sensor and also the low water cut off safety. Also remove the 1/2” copper tubes the sensors are in. Both tubes had a heavy buildup of calcium. If these tubes are not clear, they hold water they will give you false alarms. After cleaning, both copper tubes, reinstalled into the heating exchanger, then install the sensors in both the high water and low water cut off. Also clear the tubing to the side Started the unit testing the fill valve and the low water cut off. The water supply to the steam generator seems a little restricted, however it is not affecting the operation of the steam generator at this time. Steam generator is producing steam in the men’s steam room at this time. System is working.
Out today for Backdraft in flue after chimney company cobalt install the new Flexi flue and chimney liner. Upon inspection it appears that chimney liner is too small for chimney. We will have to have cobalt come back out and install a properly sized liner. Contact Damon for contact and information purposes
Followed ip
.
Expansion tank replacement
Completed furnace inspection for customer. All aspects of system tested within manufacturer specifications. No recommendations at this time. System operating normally upon departure.
Scoped main line for a real estate agent. Line is full from 50-16 ft. Needs jetting
Na