Leawood, KS Residential HVAC & Plumbing Services
LBA Heating, Cooling, Plumbing & Electrical was started by people just like you who want and insist on high quality and reliable service. In Leawood, KS and throughout the Kansas City area, we treat each family and home as if it were our own. That includes rising to the challenge of being a Hero any time the need calls for extraordinary measures.
From routine maintenance to 24/7 emergency repairs, LBA Heating, Cooling, Plumbing & Electrical has you covered for all your home plumbing, heating, and air conditioning needs. The same goes for new and replacement system installations. Read our reviews and find out why your neighbors consider us to be their nearby heating and air company and local plumber in Leawood, KS.
Recent Jobs and Reviews in Leawood, KS
Leawood, KS at a glance
LBA Air Conditioning, Heating & Plumbing has completed 25 jobs in Leawood, KS between November 2024 and December 2024.
The most recent job was on December 3, 2024.
LBA Air Conditioning, Heating & Plumbing has completed 66 jobs in Leawood, KS in the last 12 months. The first job there was in December 2014.
Our Local Reviews by City
- Adrian, MO (2)
- Avondale, MO (1)
- Basehor, KS (24)
- Bates City, MO (1)
- Belton, MO (33)
- Blue Springs, MO (72)
- Bonner Springs, KS (30)
- Buckner, MO (1)
- Bucyrus, KS (6)
- Columbia, MO (1)
- De Soto, KS (25)
- Dearborn, MO (1)
- Edwardsville, KS (14)
- Eudora, KS (9)
- Fairway, KS (93)
- Freeman, MO (1)
- Gardner, KS (14)
- Gladstone, MO (65)
- Grain Valley, MO (58)
- Grandview, MO (75)
- Greenwood, MO (3)
- Holt, MO (3)
- Houston Lake, MO (7)
- Independence, MO (184)
- Kansas City, KS (427)
- Kansas City, MO (2902)
- Kearney, MO (3)
- Lake Lotawana, MO (4)
- Lake Quivira, KS (22)
- Lake Waukomis, MO (4)
- Lake Winnebago, MO (1)
- Lansing, KS (2)
- Lawrence, KS (19)
- Leavenworth, KS (8)
- Leawood, KS (429)
- Lee's Summit, MO (164)
- Lenexa, KS (608)
- Liberty, MO (116)
- Lone Jack, MO (1)
- Louisburg, KS (5)
- Merriam, KS (21)
- Mission, KS (204)
- Mission Hills, KS (78)
- North Kansas City, MO (10)
- Northmoor, MO (1)
- Oak Grove, MO (13)
- Odessa, MO (1)
- Olathe, KS (632)
- Ottawa, KS (1)
- Overland Park, KS (1458)
- Paola, KS (1)
- Parkville, MO (191)
- Peculiar, MO (1)
- Platte City, MO (13)
- Pleasant Hill, MO (1)
- Pleasant Valley, MO (4)
- Prairie Village, KS (527)
- Prairie Village New, KS (2)
- Raymore, MO (27)
- Raytown, MO (84)
- Riverside, MO (18)
- Roeland Park, KS (189)
- Shawnee, KS (1045)
- Shawnee Mission, KS (2)
- Smithville, MO (1)
- Spring Hill, KS (13)
- Stilwell, KS (66)
- Sugar Creek, MO (7)
- Weatherby Lake, MO (31)
- Wellsville, KS (1)
- Westwood, KS (30)
- Westwood Hills, KS (18)
Job Locations and Reviews
Went for a furnace inspection today. Did a static pressure test, it passed. I changed filter due to the old one being dirty. Ducts are clean. Did a carbon monoxide leak test and a gas leak test, there is no leaks. Did a combustion analysis test, it passed. Inducer motor amperage passed. Gas pressure met factory specifications. Pressure switch passed. Temperature split between the supply and return duct passed. Blower motor amperage passed and blower wheel is clean. Humidifier works fine. I noticed the drain line Is growing biological growth inside of it. Thank you for choosing LBA services!
12-2-24 Fittness tennis Building men’s locker room is cold, found the furnace running however two of the 12” flexduct runs in the ceiling are not connected to the diffusers. There is no insulation above the ceiling only the sheet rock. The yoga room heating is not working. Found the York rooftop unit had a tripped control circuit breaker. The problem to a wire at the ignition board looks like it overheated and shorted out the ground. I ran the unit in heat mode did not have any flame rollout. All the safeties are attached. Country club building AHU#5 Blower is not running found the freeze stat is defective. Need to pick up a new freeze stat and install. Currently I lowered the setting from 35° down to about 15° AHU#3 Blower is not coming on. I tested the freeze stat on this unit, seems to be working. I removed some of the filters after a little while the unit came on , there is a filter pressure safety switch that may have not been closed due to the dirty filters. The unit is w
Completed furnace maintenance and inspection. I checked all components and amp draws, I tested airflow and temp splits. I cleaned flame sensor and cleaned up furnace. Air pressure is well over the max rating for system. I found a couple blower adjustments that helped relieve a bit of the pressure but we are still over max. I let customer know what I did and reviewed maintenance form with them. Furnace is running at departure.
Completed furnace maintenance and inspection. I checked all components and amp draws. I tested airflow and temp splits. I cleaned up furnace and flame sensor. I changed out air filter and humidifier pad. I found no major concerns with furnace today. Dampers open and closed as they should. Talked with customer about getting ductwork cleaned since it has been about 10yr or so since it was done. Furnace is operating within manufacture’s specifications at departure.
K
K
K
K
Sales
Arrive to customers for a furnace tuneup and during the process of the inspection we’ve received the high static pressure With just opening all supply register, events and changing filter, did manage to lower static pressure. We’ve also discovered a dirty blower wheel. All other components met within factory specs.
Out today to install pressure regulating valve per Murph. Removed old PRV and installed with new successfully, tested, no leaks. Also set regulator 275 psi. Cleaned up work area and collected. Paid with a card. Thank you for choosing LBA services!
During this visit I arrived at 3:30p.m. and was asked to investigate the source of the water that was reported. I did perform prevent maintenance and heating checks on the equipment at this building 5 days ago. The dentist office was helpful in showing me where the water was next to the wall that is shared with Tilted Pilates. I was unable to access Tilted Pilates due to them being closed. The dentist office also needed to close very soon and all staff needed to leave (p/u kids, etc.) I the accessed the attic and checked the units above Smiley dental. Both of their units are located away from the area of the water on the floor and were dry and there was no evidence at the units of a water backup. With the limited time allowed I discovered that the equipment room for the dentist room (located on building’s south wall just under the access window for the attic and to the right) had damp concrete from the floor drain to under the clothes washer and drier. There was also an app
Still gathering info
Estimate
Met with customer five star greeting. Found the only issue was disposal. Needed reset. Offered to take a look around for inspection. He declined and reset disposal. Make sure it works properly. Cleaned up area. Charged member trip charge.
Out today to install expansion tank. Removed failed thermal expansion tank and replaced with new, tested no leaks. Cleaned up work area and collected. Paid with a card. Thank you for choosing LBA services!
Maintenance performed by Trent.
Installed new 96% efficient 120,000 BTU gas furnace.
Re quoted
Inspected customer’s system. Found PRV is not operational. Also gave recommendation for kitchen sink replumbing to relief air pockets in drain causing back ups and old water heater replacement. Customer decided on PRV for now.
Quoted
Refer to notes written by Rob Provost
We sold a 1 star duct upgrade package, 3 germicidal Air purifiers, and 3 system duct cleaning.
Arrived to do a multi system performance maintenance. Set up for combustion analysis temperature split and static pressure tests for each separate system. Found that the main system is operating with failing static pressure. Reached out to a field supervisor to finish the diagnosis on the systems static pressure. Verified operation of all mechanical and electronic components of each furnace. Checked blowers for cleanliness and to see if there is any play in the bearings. Checked each systems heat exchanger to ensure proper venting of flue gas. Found bacterial growth present on the bottom of each evaporator coil. Performed an electronic gas leak search. Spoke with homeowner about the system. All furnaces are operational at this time.
Install 95% , 100k btu furnace and new thermostat with carbon monoxide detectors