Leawood, KS Residential HVAC & Plumbing Services
LBA Heating, Cooling, Plumbing & Electrical was started by people just like you who want and insist on high quality and reliable service. In Leawood, KS and throughout the Kansas City area, we treat each family and home as if it were our own. That includes rising to the challenge of being a Hero any time the need calls for extraordinary measures.
From routine maintenance to 24/7 emergency repairs, LBA Heating, Cooling, Plumbing & Electrical has you covered for all your home plumbing, heating, and air conditioning needs. The same goes for new and replacement system installations. Read our reviews and find out why your neighbors consider us to be their nearby heating and air company and local plumber in Leawood, KS.
Recent Jobs and Reviews in Leawood, KS
Leawood, KS at a glance
LBA Air Conditioning, Heating & Plumbing has completed 25 jobs in Leawood, KS between December 2024 and January 2025.
The most recent job was on January 7, 2025.
LBA Air Conditioning, Heating & Plumbing has completed 66 jobs in Leawood, KS in the last 12 months. The first job there was in December 2014.
Our Local Reviews by City
- Adrian, MO (2)
- Avondale, MO (1)
- Basehor, KS (24)
- Bates City, MO (1)
- Belton, MO (33)
- Blue Springs, MO (72)
- Bonner Springs, KS (30)
- Buckner, MO (1)
- Bucyrus, KS (6)
- Columbia, MO (1)
- De Soto, KS (25)
- Dearborn, MO (1)
- Edwardsville, KS (14)
- Eudora, KS (9)
- Fairway, KS (93)
- Freeman, MO (1)
- Gardner, KS (14)
- Gladstone, MO (65)
- Grain Valley, MO (58)
- Grandview, MO (75)
- Greenwood, MO (3)
- Holt, MO (3)
- Houston Lake, MO (7)
- Independence, MO (184)
- Kansas City, KS (427)
- Kansas City, MO (2902)
- Kearney, MO (3)
- Lake Lotawana, MO (4)
- Lake Quivira, KS (22)
- Lake Waukomis, MO (4)
- Lake Winnebago, MO (1)
- Lansing, KS (2)
- Lawrence, KS (19)
- Leavenworth, KS (8)
- Leawood, KS (429)
- Lee's Summit, MO (164)
- Lenexa, KS (608)
- Liberty, MO (116)
- Lone Jack, MO (1)
- Louisburg, KS (5)
- Merriam, KS (21)
- Mission, KS (204)
- Mission Hills, KS (78)
- North Kansas City, MO (10)
- Northmoor, MO (1)
- Oak Grove, MO (13)
- Odessa, MO (1)
- Olathe, KS (632)
- Ottawa, KS (1)
- Overland Park, KS (1458)
- Paola, KS (1)
- Parkville, MO (191)
- Peculiar, MO (1)
- Platte City, MO (13)
- Pleasant Hill, MO (1)
- Pleasant Valley, MO (4)
- Prairie Village, KS (527)
- Prairie Village New, KS (2)
- Raymore, MO (27)
- Raytown, MO (84)
- Riverside, MO (18)
- Roeland Park, KS (189)
- Shawnee, KS (1045)
- Shawnee Mission, KS (2)
- Smithville, MO (1)
- Spring Hill, KS (13)
- Stilwell, KS (66)
- Sugar Creek, MO (7)
- Weatherby Lake, MO (31)
- Wellsville, KS (1)
- Westwood, KS (30)
- Westwood Hills, KS (18)
Job Locations and Reviews
Inspected water heater turned over to supervisor
Spoke with Andrew. He has grounded flame sensor. We will need a new board, flame sensor, and wire harness. Scheduled for tomorrow morning. Wife will be available.
Arrived and took off clean out cap to main stack. Ran 500 machine down the line about 75 feet. For that through tested for the water was running properly. So I Collected signatures and headed out.
1-3-25 Equipment storage area And the maintenance room All five Lennox unit heaters Plus the two heater units in the maintenance room Performed heating check Did visual inspection of the heat exchanger Clean flame sensor and ignition rod Use compressed air to blow out the burner offices and burner ribbons Check blower wheels, and motors The two unit heaters in the maintenance shop are both tied into the same thermostat. This has been like this for many years All the units are working at this time
Customer called for system not heating. Upon arrival found blower fan running but no inducer. Reset furnace as it was in a lock out, furnace began heat sequence and lit, allowed system to run for a few minutes and put top door on and flames extinguished. Checked flues to ensure no obstruction and found there was screen in exhaust flue which can build moisture and freeze prevent system from running as well as customers grill with a cover set in front of flues. Exhaust was potentially hitting grill cover and dispersing around and being drawn into fresh air so furnace was re-cycling exhaust fumes and dying. Removed screen and moved grill and system is operating normally now. System satisfied upon departure.
12-31-24 Building heating hot water system pump seal is leaking. Leftside Armstrong pump seal is bad leaking. I also checked my isolation valves. They do hold so we can pull that pump and replace the seals once I get some information on that part of it.
Customer called for malfunctioning furnace. Found that furnace control board was failed and throwing a code and turning itself off, also found inducer to be in very poor condition. Replaced both components for customer. System operating normally upon departure.
Clean and seal
Found water not draining from the system. Air was back flowing causing water to no drain from the unit. I fixed that and system ran without issue for over 30 minutes.
Estimate
The condenser for the kitchen and dining room is severely unlevel outside. It needs to be re-leveled so that we don’t blow out the fan or worse the condenser. Secondly downstairs we have condensation issues because the water heater is too close to the supply duct of the 4 ton system. Because of this, it is condensating in the summer which is creating rust And damaging the duct as well as the water heater below it. We either need to put insulated duct in or move the water heater. We are coming out tomorrow to re-leveled the condenser and move the water heater.
Went for a maintenance call today. Tested for static pressure on furnace and was failing. Did adjust blower speeds and was stilling failing. Did notice rust forming on supply duct work. Notified customer on having a supervisor to take a look on why. Did also see blower wheel has a lot of dust on blower wheel. Did a co test, no co was detected when testing. All electrical components are passing for system. Temp split is passing as well. As well as for the air handler. All electrical components are passing for both indoor and outdoor. Temp split is passing. Static pressure is passing. No wear and tear on air handler. Furnace has dirty blower, and failing static. Supervisor will have solutions for customer.
Installed 2 50 gal water heaters w/ expansion tanks and 2 new AprilAire 600 Humidifiers.
Furnace is up and heating.
Follow up
12-20-24 Fitness building yoga room Diego and I installed new heat exchanger in York rooftop unit. After installing all plates, mounting the inducer motor reinstalling the circuit board and electrical. Components we tested for gas leaks, then burned off the heat exchanger. Also, John supplied us with Hallbrook with new filters and a new blower belt, which we installed. System is currently working at this time. Quote to replace the failed heat exchanger in the York package unit serial N1B3480474 for the Fitness Center Yoga room. Price includes the factory replacement heat exchanger and labor. Repairs covered by a one year parts and labor warranty.
Taking up space heaters
Out today for a couple of issues after install, namely the pull bar in hall bath is not present, however, there is no clearance behind the faucet for it. We will order a brushed nickel push in stopper to replace it with, upstairs bathroom widespread faucet is also missing pop-up rod, which we will also return to replace. When parts are sourced and ordered, we will reach out to schedule. Thank you for choosing LBA services!
Full system
Quotes for various water heaters and filters
Inspected water heater and other areas of concern, turned over to supervisor
Replace the solenoid valve for the humidifier came to the conclusion that that’s where the vibration was coming from. Makes sense due to one side of it being clogged and starving for water.
Installed Two New 80% Single Stage Furnaces. FR801T0754A21UHSNA & FR801T1005A21UHSNA 2 Year Labor Warranty 10 Year Parts Warranty Limited Lifetime Heat Exchanger Warranty
Installed Two New 80% Single Stage Furnaces. FR801T0754A21UHSNA & FR801T1005A21UHSNA 2 Year Labor Warranty 10 Year Parts Warranty Limited Lifetime Heat Exchanger Warranty
Installed Two New 80% Single Stage Furnaces. FR801T0754A21UHSNA & FR801T1005A21UHSNA 2 Year Labor Warranty 10 Year Parts Warranty Limited Lifetime Heat Exchanger Warranty