Leawood, KS Residential HVAC & Plumbing Services
LBA Heating, Cooling, Plumbing & Electrical was started by people just like you who want and insist on high quality and reliable service. In Leawood, KS and throughout the Kansas City area, we treat each family and home as if it were our own. That includes rising to the challenge of being a Hero any time the need calls for extraordinary measures.
From routine maintenance to 24/7 emergency repairs, LBA Heating, Cooling, Plumbing & Electrical has you covered for all your home plumbing, heating, and air conditioning needs. The same goes for new and replacement system installations. Read our reviews and find out why your neighbors consider us to be their nearby heating and air company and local plumber in Leawood, KS.
Recent Jobs and Reviews in Leawood, KS
Leawood, KS at a glance
LBA Air Conditioning, Heating & Plumbing has completed 25 jobs in Leawood, KS between January 2025 and February 2025.
The one customer review shown here is rated 5.0 out of 5.
The most recent job was on February 7, 2025.
LBA Air Conditioning, Heating & Plumbing has completed 66 jobs in Leawood, KS in the last 12 months. The first job there was in December 2014.
Our Local Reviews by City
- Adrian, MO (2)
- Avondale, MO (1)
- Basehor, KS (24)
- Bates City, MO (1)
- Belton, MO (33)
- Blue Springs, MO (72)
- Bonner Springs, KS (30)
- Buckner, MO (1)
- Bucyrus, KS (6)
- Columbia, MO (1)
- De Soto, KS (25)
- Dearborn, MO (1)
- Edwardsville, KS (14)
- Eudora, KS (9)
- Fairway, KS (93)
- Freeman, MO (1)
- Gardner, KS (14)
- Gladstone, MO (65)
- Grain Valley, MO (58)
- Grandview, MO (75)
- Greenwood, MO (3)
- Holt, MO (3)
- Houston Lake, MO (7)
- Independence, MO (184)
- Kansas City, KS (427)
- Kansas City, MO (2902)
- Kearney, MO (3)
- Lake Lotawana, MO (4)
- Lake Quivira, KS (22)
- Lake Waukomis, MO (4)
- Lake Winnebago, MO (1)
- Lansing, KS (2)
- Lawrence, KS (19)
- Leavenworth, KS (8)
- Leawood, KS (429)
- Lee's Summit, MO (164)
- Lenexa, KS (608)
- Liberty, MO (116)
- Lone Jack, MO (1)
- Louisburg, KS (5)
- Merriam, KS (21)
- Mission, KS (204)
- Mission Hills, KS (78)
- North Kansas City, MO (10)
- Northmoor, MO (1)
- Oak Grove, MO (13)
- Odessa, MO (1)
- Olathe, KS (632)
- Ottawa, KS (1)
- Overland Park, KS (1458)
- Paola, KS (1)
- Parkville, MO (191)
- Peculiar, MO (1)
- Platte City, MO (13)
- Pleasant Hill, MO (1)
- Pleasant Valley, MO (4)
- Prairie Village, KS (527)
- Prairie Village New, KS (2)
- Raymore, MO (27)
- Raytown, MO (84)
- Riverside, MO (18)
- Roeland Park, KS (189)
- Shawnee, KS (1045)
- Shawnee Mission, KS (2)
- Smithville, MO (1)
- Spring Hill, KS (13)
- Stilwell, KS (66)
- Sugar Creek, MO (7)
- Weatherby Lake, MO (31)
- Wellsville, KS (1)
- Westwood, KS (30)
- Westwood Hills, KS (18)
Job Locations and Reviews
Put caps on outdoor refrigerate lines
Came out here for a furnace tuneup on arrival tested static static was failing. Customer was aware and is not doing anything due to her moving homes took a look at the rest of the unit cleaned out flame sensor, replace filter and ensured that The heating cycle was working perfectly fine. No carbon monoxide readings within the ductwork Ran a combustion analysis on the unit all numbers seem to fall within what we wanted to see I did see at the inducer motor itself was starting to leak as well as the collector box which I did mention to the customer customer decide to get those sent to her email thank you for choosing LBA services
Out today to perform proposed work. Installed new pressure regulator, as well as shut off, tested no leaks. Cleaned up work area and collected paid with a card. Thank you for choosing LBA services!
Technician unable to source parts due to parts house mistakenly not ordering lift rod for faucet. They are re-ordering and we will reschedule when parts are sourced. Thank you for choosing LBA Services!
Out today to replace laundry valves with new. Did so successfully at this time, tested, no leaks. Cleaned up work area and collected, paid with a card. Thank you for choosing LBA services!
N/A
New prv/shutoff install, $927. Tuesday morning works for him.
Inspected main shut off turned over to supervisor
Permit Submitted to the City of Leawood Installed new Full System 2 year labor warranty 10 year parts warranty
Arrived to perform previously diagnosed repairs. System is still making a vibration noise. Determined the water feed system needs replaced due to calcium causing cavitation inside the water line. Mocked up the quarter inch feed line from the shutoff by the water heater to the solenoid valve on the humidifier. Replaced the solenoid valve and connected it to the new water line. Secured and isolated/insulated the water feed line all the way to the water heater. Removed the old shut off from the homes plumbing and installed a new one. Trimmed and connected the new water feed line to the new shutoff valve. Turned water back on to the water heater and checked system for leaks, cleaning and drying my mess. Turned the system on and tested humidifier operations. Humidifier is operating normally without any vibration noises.
Sold furnace and ac
Came out for a no heat unit will shut off and restart about 3 times before coming on due to the safety on the unit it would hold of to turn on unit would shut the gas on and off took a look at heat exchanger and found many concerns called supervisor to come out and review what I have found with me as well customer and field supervisor taking a look now
Sold replace faucet and fix waterline
Inspected outside water line, and water quality turned over to supervisor
Arrived to remedy a humidifier that’s making a vibration noise throughout the house. Adjusted the humidity set point and tried determining the source of the vibration. Determined that it was the fan that was causing the vibration. Tried supporting and securing the return duct a little better than the original installation, and that didn’t resolve the noise issue. Spoke with homeowner about replacing the humidifier to one without a fan. Went to turn water off to the existing humidifier and felt that the shutoff valve on the plumbing line was vibrating. Turned up the water pressure and the vibration got worse. Checked the humidifier side of the solenoid valve and found no metering orifice in place. Installed a new one to ensure the humidifier is supplying the correct amount of water. Removed the small copper feed line to the humidifier and performed a flush to remove any calcium buildup that may be inside. Reassembled the humidifier and tested operations. Found that the humidifier would
Replaced power vent water heater with new Rheem power vent. Disposed of old unit. Bring new unit up to code. Check operation and for leaks.
Sold w heater
Inspected water heater turned over to supervisor
Completed water heater flush. Installed new quarter turn for humidifier and tested humidifier to make sure it was working correctly. Capped off old saddle valve. Tested hardness and it was at four grains, which is good. Softener and humidifier seem to be working good as well as water heater
Tested water heater. Returning Monday to make sure softener system is working correctly and flushing water heater.
1-24-25 Installed customer supplied zoning system and made some other repairs. I will finish my notes Monday morning.
Upon arrival I began the furnace tune up. First, I ran a static pressure test. Your system is rated for 1.0 maximum static pressure and your system is testing at .7 which is passing. Next, I checked the running amps on the inducer and blower motor and both were testing within manufacturer specifications. I changed out the filter today with size 20x25x1 inch high velocity filter. I took a temp split on the system as well. The unit says it should be between 40 to 70 degrees and it’s testing at a 43 degree temp rise which is within specs. Your system is running properly at this time. If you have any questions or concerns please feel free to call us! Your LBA Technician, Tyler Rickard P.S. I took payment in the form of canned goods for our food drive. Thanks for participating and have a great weekend ahead!
1-22-25 Equipment repair garage, the north Reznor unit heater is having intermittent problems and not staying lit. Upon arrival, turn the thermostat on. I do have a call for heat. The unit was light, but then it was adelay ignition. I pulled the burner cover, pull the pilot assembly, but I went to go clean this pilot The igniter rod actually broke off. I did locate a new pile of assembly for this unit due to its age. This is not a common pilot. Install the new pilot I also blew out the burner ribbons pull the burner orifice and clean them. They were about half clogged. I got the unit de light however, the flames looked real weak. I checked the burner gas pressure. It was at 2.4” WC These units recommend at least 3.5” WC.I said it at 3.75”Wc I did check the heat exchanger for any cracks. There was one hairline crack at the lower lower section in the center port. There was no soup buildup on this unit at all mostly just rust and dirt from the garage.
Needs friday
Out today for pipe freeze and burst in crawlspace. Upon inspection discovered that freeze up was at a point of very easy access, installed bleeder valve and insulated lines, tested no leaks. Cleaned up work area and collected paid with a card. Thank you for choosing LBA Services!
I just wanted to say thank you lba for the great job your techs do