Kansas City, KS Residential HVAC & Plumbing Services
LBA Heating, Cooling, Plumbing & Electrical was started by people just like you who want and insist on high quality and reliable service. In Kansas City, KS and throughout the Kansas City area, we treat each family and home as if it were our own. That includes rising to the challenge of being a Hero any time the need calls for extraordinary measures.
From routine maintenance to 24/7 emergency repairs, LBA Heating, Cooling, Plumbing & Electrical has you covered for all your home plumbing, heating, and air conditioning needs. The same goes for new and replacement system installations. Read our reviews and find out why your neighbors consider us to be their nearby heating and air company and local plumber in Kansas City, KS.
Recent Jobs and Reviews in Kansas City, KS
Kansas City, KS at a glance
LBA Air Conditioning, Heating & Plumbing has completed 25 jobs in Kansas City, KS between August 2025 and September 2025.
The 25 customer reviews shown here average 4.9 out of 5.
The most recent job was on September 9, 2025.
LBA Air Conditioning, Heating & Plumbing has completed 133 jobs in Kansas City, KS in the last 12 months. The first job there was in December 2014.
Our Local Reviews by City
- Adrian, MO (2)
- Avondale, MO (1)
- Basehor, KS (24)
- Bates City, MO (1)
- Belton, MO (33)
- Blue Springs, MO (72)
- Bonner Springs, KS (30)
- Buckner, MO (1)
- Bucyrus, KS (6)
- Columbia, MO (1)
- De Soto, KS (25)
- Dearborn, MO (1)
- Edwardsville, KS (14)
- Eudora, KS (9)
- Fairway, KS (93)
- Freeman, MO (1)
- Gardner, KS (14)
- Gladstone, MO (65)
- Grain Valley, MO (58)
- Grandview, MO (75)
- Greenwood, MO (3)
- Holt, MO (3)
- Houston Lake, MO (7)
- Independence, MO (184)
- Kansas City, KS (427)
- Kansas City, MO (2902)
- Kearney, MO (3)
- Lake Lotawana, MO (4)
- Lake Quivira, KS (22)
- Lake Waukomis, MO (4)
- Lake Winnebago, MO (1)
- Lansing, KS (2)
- Lawrence, KS (19)
- Leavenworth, KS (8)
- Leawood, KS (429)
- Lee's Summit, MO (164)
- Lenexa, KS (608)
- Liberty, MO (116)
- Lone Jack, MO (1)
- Louisburg, KS (5)
- Merriam, KS (21)
- Mission, KS (204)
- Mission Hills, KS (78)
- North Kansas City, MO (10)
- Northmoor, MO (1)
- Oak Grove, MO (13)
- Odessa, MO (1)
- Olathe, KS (632)
- Ottawa, KS (1)
- Overland Park, KS (1458)
- Paola, KS (1)
- Parkville, MO (191)
- Peculiar, MO (1)
- Platte City, MO (13)
- Pleasant Hill, MO (1)
- Pleasant Valley, MO (4)
- Prairie Village, KS (527)
- Prairie Village New, KS (2)
- Raymore, MO (27)
- Raytown, MO (84)
- Riverside, MO (18)
- Roeland Park, KS (189)
- Shawnee, KS (1045)
- Shawnee Mission, KS (2)
- Smithville, MO (1)
- Spring Hill, KS (13)
- Stilwell, KS (66)
- Sugar Creek, MO (7)
- Weatherby Lake, MO (31)
- Wellsville, KS (1)
- Westwood, KS (30)
- Westwood Hills, KS (18)
Job Locations and Reviews
Arrived for ac check today? Started at furnace and checked static pressure, it’s running under the max. Blower wheel is clean. Motor amps are good. There is a 20 degree temp split. At the condensing unit I cleaned the coil. Compressor and fan amps are good. Capacitor tested with in range. Refrigerant levels are good. Next I cleaned the coil on the mini split system. I cleaned all filters. Coils were clean. Both heads had 20 degree temp splits. All systems are running upon departure. Thanks for choosing LBA.
B
…
Added saftey and pump to ensure system would disengage if a problem occurred
Arrived to assess a system to be replaced. Upon inspection of the system found a 2018 furnace and evaporator coil. Found water on the floor around the furnace. Cleared the restriction in the condensation drain line. Opened up the evaporator coil and found that the standing condensation has caused some premature rust on the evaporator coil. Checked the blower wheel for cleanliness and found it coated in dust debris. Tested systems static pressure and found it operating with nearly double the static pressure the system is rated for. Used an inspection camera to inspect the bottom side of the evaporator coil and found it impacted with debris. Went outside and checked the outside unit. Found that the system is an r22 system and this refrigerant has been discontinued for more than a decade. Rinsed condenser coil free of debris while field supervisor put together pricing information on some bundled repairs and cleanings. Presented options to clean system and bring it within compliance with b
Duct cleaning
Today I checked in and was told that the A/C in the shop office was not cooling. The rooftop unit that serves the shop office had a thermostat that was on the date and time setting. The thermostat was forwarded past the date and time settings and the unit returned to cooling. The temp split was checked and was in range (18degf). This system was documented as not functioning in heat mode when it’s maintenance was performed. I checked the heating functions today. The system has returned to cooling. Thank you, Jon Tech notes: KGA060S4DH3Y//5612D05031 Rollout and high temp limit closed 24v at one side of the pressure switch Inducer 208/230 (no voltage present), ind. cap 1.3 (rated 2) Control board not passing voltage to inducer due to 3blink failure code.
Drain pan was filled with water. Cleaned the water out. Wet switch wasn’t in the drain Pan. Wet switch is back in the pan. System is draining properly. Thank you for choosing LBA services!
Today I arrived for a heating maintenance units 1-4 have no problems got all my temp splits changed filters n got all amp draws. Until 5 has a breached heat exchanger will need replacement. All other functions working as should. Until 6 is not working on the heat side. Service call during heat exchange change out.
Replaced the prv.
****(***)*)*)*)*)**)*))*)*)*)*)*)*)*)* Parts sourced from our shop. Tom said the switch is $0.97. Rounded to $2 min and applied markup. $12.38 total. ***(())*)*(&((***&(&&)(&(&&&&*&*****)*( Today the 80% Rheem split system that serves the office was off when I arrived. The system was started and checked. There was not an error code to reference when I arrived. The A/C system checked out properly however the cabinet switch had a buzzing sound. The cabinet switch was replaced. During this the breaker box was not labeled for the furnace. The breaker for the furnace was located and is now labeled. After the repair the system returned to normal function. Thank you, Jon Tech notes: Rheem, R801CA100521MSA//W062141145 Line voltage 120.3, control voltage 26.8, blower amps 8.1, temp split 20 (78-58), filters clean,
Dispatched for annual AC tuneup. At arrival system is operating. During the tuneup, I checked compressor, fan and capacitor. Also, during the inspection we checked pressures, static pressure, and temperature split. All components of the AC are all operating with manufacturer specs. Thank you for allowing us in your house to provide the perfect home service and for being a member of the perfect family service club from your LBA Service tech Calvin. If I provided a positive or five star experience. I’d appreciate you sharing your thoughts in a review.
Replace the existing Carrier 60,000 btu cooling package unit with gas serial 1107G40243. Price includes a Carrier 60,000 btu cooling package unit with gas. Existing ductwork, room thermostat, electrical disconnect and utilities will be reused.
Went for an outage in system. Furnace wasn’t receiving correct voltage on system. Breaker is weak reason for system not being able to turn system on. Will need to be replaced. Thank you for choosing LBA services-Johann
Just a duct clean that’s all the customers
Quoted for repair
8-20-25 I have more work out here on the Dakin hallway, make up units and also on the beer cooler
8-20-25 Got information on RTU #7 , north east corner office system. They would like a quote on repairs and or replacing the unit There is a definite, bad heat exchange also the ignition module and gas valve looks like it’s been replaced, but it’s not working. The AC system I did not see any physical damage and it seems to be working with a decent evaporator split of 18° Lennox Model #GCS24-953-200-1Y Serial #5696K04372 ============================================ RTU #6 Kids play area is the south east corner Air conditioner is not keeping up Found the thermostat was only set for a single stage cooling. This is a two stage system. I also found the first stage evaporator is got a good amount of ice on the distributor tubes and I can feel oil on the distributor tube flare nut. We need to do a leak search and repair, time and material and also set the thermostat up for for multi stage If the leak is where I think it is, 4 hours plus refrigerant I would weigh in the refrigerant R4
System basically flat on freon(r22) Lane quoting system
…
Filter was changed 18° temp split Fan motor outside is a tad above spec and compressor is within spec(upper end) Blower motor is within spec but also the upper end. When we check the furnace this winter(preferably earlier in winter) he may be willing to do a system replacement.
Checked amps on blower, condenser fan motor, and compressor. All looks good. Customer does a great job cleaning the outdoor coils. Adjusted blower a tad lower to raise his temp split from 15° to 17°. System is running and coil drain is clear/dumping water.
(*******(*************(**** I will relay to Elle a schedule request for a leak search and subsequent repair after leak found. So far no results on leak searches. ***(********(******(********((*******((**((*** Checked the unit that serves the office. The system was functioning when I arrived but was not cooling well. The filter was packed and the filter for the tech room was also packed. Both filters were replaced. The refrigerant charge was adjusted. A quick leak search was performed inside due to wet conditions on the roof. The system charge was adjusted. A leak search for this system will be scheduled for dryer weather. This system has returned to cooling. Thank you, Jon
Dispatched for not cooling. At arrival system was froze over. After thawing the system. Performed a thorough inspection of the whole system. It was determined to be over charged. Adjust refrigerant and system is cooling properly.
I’m not backflow certified. Bpu had given customer a sheet to fill out.
Very excellent service
Great Service
Great Tech
Great service, Awesome price!
Chris and his coworker were very professional and knowledgeable to fix the problem I was having very happy with the results
Danny was informative, polite and a pleasure to work with
Have used LBA for 20 years and am comfortable with their expertise. Nick is always courteous and helpful with my concerns.
Phil was great to work with. He was super knowledgeable and very willing to talk me through even small plumbing issues. He gave me all the time I needed to talk through my options.
To replace just a condenser motor was quoted at $825. The cost for the motor would have been charged at $300. This is a simple, and fast repair. $525 for labor is outrageous.
Andrew was right on time and he was very knowledgeable, friendly and professional.
Noah was great, he was professional, knowledgeable and friendly.
I have been very pleased with the gentlemen who has working to install the new ac systems in my home they have been very polite and kind and sweet and hard young men I would be happy to recommend your company to anyone thank you so much
Informative
Tech was very knowledgeable and explained all options.
He was friendly and shared the details as he was working.
James was polite and very courteous. Very informative. He noticed I had an Army hat and ask me about my service. Explain to me what he needed to do. Great interaction.
Fixed in a timely manner. No issues with Al
Called in the AM and job was finished by 2 PM. They checked the system and had to installed a new thermostat. Gave the rest of the system a once over and were done. Good job!!
Pat was very upfront and knowledgeable/professional!
Great service
Great Service!
Awesome guy
Loved our tech
as always the service was fast and done right
did a terrific job and wore a mask all of the time this was great