Independence, MO Residential HVAC & Plumbing Services
LBA Heating, Cooling, Plumbing & Electrical was started by people just like you who want and insist on high quality and reliable service. In Independence, MO and throughout the Kansas City area, we treat each family and home as if it were our own. That includes rising to the challenge of being a Hero any time the need calls for extraordinary measures.
From routine maintenance to 24/7 emergency repairs, LBA Heating, Cooling, Plumbing & Electrical has you covered for all your home plumbing, heating, and air conditioning needs. The same goes for new and replacement system installations. Read our reviews and find out why your neighbors consider us to be their nearby heating and air company and local plumber in Independence, MO.
Recent Jobs and Reviews in Independence, MO
Independence, MO at a glance
LBA Air Conditioning, Heating & Plumbing has completed 25 jobs in Independence, MO between May 2025 and June 2025.
The most recent job was on June 5, 2025.
LBA Air Conditioning, Heating & Plumbing has completed 59 jobs in Independence, MO in the last 12 months. The first job there was in January 2015.
Our Local Reviews by City
- Adrian, MO (2)
- Avondale, MO (1)
- Basehor, KS (24)
- Bates City, MO (1)
- Belton, MO (33)
- Blue Springs, MO (72)
- Bonner Springs, KS (30)
- Buckner, MO (1)
- Bucyrus, KS (6)
- Columbia, MO (1)
- De Soto, KS (25)
- Dearborn, MO (1)
- Edwardsville, KS (14)
- Eudora, KS (9)
- Fairway, KS (93)
- Freeman, MO (1)
- Gardner, KS (14)
- Gladstone, MO (65)
- Grain Valley, MO (58)
- Grandview, MO (75)
- Greenwood, MO (3)
- Holt, MO (3)
- Houston Lake, MO (7)
- Independence, MO (184)
- Kansas City, KS (427)
- Kansas City, MO (2902)
- Kearney, MO (3)
- Lake Lotawana, MO (4)
- Lake Quivira, KS (22)
- Lake Waukomis, MO (4)
- Lake Winnebago, MO (1)
- Lansing, KS (2)
- Lawrence, KS (19)
- Leavenworth, KS (8)
- Leawood, KS (429)
- Lee's Summit, MO (164)
- Lenexa, KS (608)
- Liberty, MO (116)
- Lone Jack, MO (1)
- Louisburg, KS (5)
- Merriam, KS (21)
- Mission, KS (204)
- Mission Hills, KS (78)
- North Kansas City, MO (10)
- Northmoor, MO (1)
- Oak Grove, MO (13)
- Odessa, MO (1)
- Olathe, KS (632)
- Ottawa, KS (1)
- Overland Park, KS (1458)
- Paola, KS (1)
- Parkville, MO (191)
- Peculiar, MO (1)
- Platte City, MO (13)
- Pleasant Hill, MO (1)
- Pleasant Valley, MO (4)
- Prairie Village, KS (527)
- Prairie Village New, KS (2)
- Raymore, MO (27)
- Raytown, MO (84)
- Riverside, MO (18)
- Roeland Park, KS (189)
- Shawnee, KS (1045)
- Shawnee Mission, KS (2)
- Smithville, MO (1)
- Spring Hill, KS (13)
- Stilwell, KS (66)
- Sugar Creek, MO (7)
- Weatherby Lake, MO (31)
- Wellsville, KS (1)
- Westwood, KS (30)
- Westwood Hills, KS (18)
Job Locations and Reviews
quote to replace two hose bibs
.
Na
Frank, the husband works Monday - Friday until 7pm. So we went over everything on the phone, with the basement being finished and the equipment / duct work only being 3 years old he’s not wanting to spend the money on the ductwork , especially since the basement is finished , he’s not wanting to tear down any ceilings / so forth
Spoke to Jess on the phone and emailed his duct cleaning estimate over. Also talked about aeroseal but it’s a rental property so he isn’t looking at doing something like that for his tenants.
Thursday afternoon: new prv, new waterline ran to fridge.
EST
DNS
Completed ac inspection. All components tested to manufacture specifications. No recommendations at this time
Arrived to do a performance maintenance. Set system for cooling. Measured the systems static pressure measured a temperature split between return and supply air. Found that the system is operating with failing static pressure and is only cooling the air 15 degrees. Checked interior of the furnace for cleanliness. Found large hotspots on the heat exchanger and rust on the evaporator coil. Went outside and verified refrigerant levels. Verified operation of all electronic and mechanical components. Rinsed coil free of debris. Spoke with homeowner about the system. Set up a time for a field supervisor to finish the diagnosis on the systems static pressure. Air conditioning system is operational at this time.
Arrived to perform previously diagnosed repairs. Disassembled the power head and removed the control board from its mount. Removed the blower wheel and blower motor. Installed the new motor and blower wheel. One by one removed plugs from the old control board and connected them to the new one. Slid the board into the mount and reassembled the power head. Started the unit up and was getting a flashing light and the unit was not operating. Performed minor diagnostic and double checked my repair. Reached out to tech support to aid in diagnosing this issue. After going through this process with tech support, the technician said that all components are testing well and all the proper voltage is in the proper places. System was still not operating. Cycled power a couple times while testing my own suspicions. System started operating like normal. Air conditioning system is operational upon departure.
B
Estimate
Completed drain clearing
Arrived to do a performance maintenance. Set system for cooling. Measured the systems static pressure measured a temperature split between return and supply air. Checked interior of the furnace for cleanliness. Found excessive bacterial growth present. Found that the evaporator coil and the blower wheel are heavily coated in debris. Went outside and verified refrigerant levels. Verified operation of all electronic and mechanical components. Found that the capacitor is failing. Pulled debris from the inside of the condenser. Spoke with homeowner about the system. Air conditioning system is operational at this time.
EST on dig
.
Rescheduled
Today the filters were replaced in the five rooftop units. A visual inspection was also completed. The panels were confirmed to be secured after the filter replacement. Thank you, Jon
Indoor squirrel cage pulled and cleaned. Installed AC coil 454B. Charged unit.
Today, 6 split-systems had preventative maintenance and cooling checks performed. The mini-splits were also cleaned and maintenance performed. All units were operated, checked, filters replaced, washed and drains cleared.
14 seer , 2.5 ton a/c coil, 12x24 return drop, blower wheel clean sold for tomorrow . Ducts will be cleaned another day 9
Arrived to do a performance maintenance. Set system for cooling. Measured the systems static pressure measured a temperature split between return and supply air. Found that the systems static pressure is higher than my gage can read. Checked interior of the furnace for cleanliness. Found that the blower wheel is heavily coated in dust and debris impeding how much air the system can move. Found that the evaporator coil is impacted with debris further interrupting systems airflow. Checked ductwork looking for the source of all the debris. Found excessive dust and debris in the ductwork, both before and after the filter. Went outside and verified refrigerant levels. Found that the system is showing that it is overcharged. This is to be expected when the evaporator coil is dirty like this. Verified operation of all electronic and mechanical components. Found that the capacitor in the condenser is failing and causing the compressor to draw more power to run. Rinsed coil free of debris. Spok
NdhnfmhnGr
Arrived to do a performance maintenance. Set system for cooling. Measured the systems static pressure measured a temperature split between return and supply air. Found that the system is operating with failing static pressure. Homeowner declined finishing the diagnosis on the systems static pressure. Checked interior of the furnace for cleanliness. Found that the evaporator coil is starting to collect debris and the blower wheel is heavily coated in debris. Went outside and verified refrigerant levels. Verified operation of all electronic and mechanical components. Rinsed coil free of debris. Spoke with homeowner about the system. Air conditioning system is operational at this time.