Independence, MO Residential HVAC & Plumbing Services
LBA Heating, Cooling, Plumbing & Electrical was started by people just like you who want and insist on high quality and reliable service. In Independence, MO and throughout the Kansas City area, we treat each family and home as if it were our own. That includes rising to the challenge of being a Hero any time the need calls for extraordinary measures.
From routine maintenance to 24/7 emergency repairs, LBA Heating, Cooling, Plumbing & Electrical has you covered for all your home plumbing, heating, and air conditioning needs. The same goes for new and replacement system installations. Read our reviews and find out why your neighbors consider us to be their nearby heating and air company and local plumber in Independence, MO.
Recent Jobs and Reviews in Independence, MO
Independence, MO at a glance
LBA Air Conditioning, Heating & Plumbing has completed 25 jobs in Independence, MO between October 2024 and November 2024.
The most recent job was on November 8, 2024.
LBA Air Conditioning, Heating & Plumbing has completed 59 jobs in Independence, MO in the last 12 months. The first job there was in January 2015.
Our Local Reviews by City
- Adrian, MO (2)
- Avondale, MO (1)
- Basehor, KS (24)
- Bates City, MO (1)
- Belton, MO (33)
- Blue Springs, MO (72)
- Bonner Springs, KS (30)
- Buckner, MO (1)
- Bucyrus, KS (6)
- Columbia, MO (1)
- De Soto, KS (25)
- Dearborn, MO (1)
- Edwardsville, KS (14)
- Eudora, KS (9)
- Fairway, KS (93)
- Freeman, MO (1)
- Gardner, KS (14)
- Gladstone, MO (65)
- Grain Valley, MO (58)
- Grandview, MO (75)
- Greenwood, MO (3)
- Holt, MO (3)
- Houston Lake, MO (7)
- Independence, MO (184)
- Kansas City, KS (427)
- Kansas City, MO (2902)
- Kearney, MO (3)
- Lake Lotawana, MO (4)
- Lake Quivira, KS (22)
- Lake Waukomis, MO (4)
- Lake Winnebago, MO (1)
- Lansing, KS (2)
- Lawrence, KS (19)
- Leavenworth, KS (8)
- Leawood, KS (429)
- Lee's Summit, MO (164)
- Lenexa, KS (608)
- Liberty, MO (116)
- Lone Jack, MO (1)
- Louisburg, KS (5)
- Merriam, KS (21)
- Mission, KS (204)
- Mission Hills, KS (78)
- North Kansas City, MO (10)
- Northmoor, MO (1)
- Oak Grove, MO (13)
- Odessa, MO (1)
- Olathe, KS (632)
- Ottawa, KS (1)
- Overland Park, KS (1458)
- Paola, KS (1)
- Parkville, MO (191)
- Peculiar, MO (1)
- Platte City, MO (13)
- Pleasant Hill, MO (1)
- Pleasant Valley, MO (4)
- Prairie Village, KS (527)
- Prairie Village New, KS (2)
- Raymore, MO (27)
- Raytown, MO (84)
- Riverside, MO (18)
- Roeland Park, KS (189)
- Shawnee, KS (1045)
- Shawnee Mission, KS (2)
- Smithville, MO (1)
- Spring Hill, KS (13)
- Stilwell, KS (66)
- Sugar Creek, MO (7)
- Weatherby Lake, MO (31)
- Wellsville, KS (1)
- Westwood, KS (30)
- Westwood Hills, KS (18)
Job Locations and Reviews
N
N
N
Called and quoted $120 for humidifier repairs. Customer accepted.
Found existing sediment filter leaking at fittings. Had to replace due to twist it out threads. Cleaned up work area did not collect.
Customer did not answer phone
11-4-24 Got information to replace the body cooler evaporator coil and also quote to replace the entire cooler unit into a box unit
Clean w dryer vents
.
10-31-24 Performed heating check out for Lennox rooftop units. See attached sheets and proposals.
Confirmed static pressure issues. CFM counts are off. There are several other factors in play here. Full system replacement is an option if we can get both of them together.
Waiting for customer to call with a RTP day and time
Went for a furnace maintenance call today. Did a static pressure test it failed. Did a carbon monoxide leak test, got a very small reading of CO. Heat exchanger had no cracks or stress marks. Combustion analysis test passed. Inducer amperage passed. Gas pressure met factory specifications. Pressure switch passed. Temperature split between the supply and return duct passed. The inside of the ductwork was very dirty. Thank you for choosing LBA services!
Arrived to do a performance maintenance. Set up for combustion analysis and static pressure tests. Found that the system is operating with failing static pressure. Reached out to a field supervisor to finish the diagnosis on the systems static pressure. Verified operation of all mechanical and electronic components in the furnace. Found that the bearings for the inducer are failing and causing excessive noise and heat. Cleaned the flame sensor and retested its performance. Checked blower for cleanliness and to see if there is any play in the bearings. Found that the blower wheel is heavily coated in debris. Checked systems heat exchanger to ensure proper venting of flue gas. Found that the heat exchanger is heat stressed, showing hot spots, and the condensation pan for the evaporator coil is coated in biological growth as well as the coil it’s self being impacted with debris. Checked for carbon monoxide in the air stream. Performed an electronic gas leak search. Spoke with homeowner ab
10-31-24 Work @ Speaks suburban Chapel The box evaporator needs to thaw out
Address changed to the correct location
Out today for T&P valve still actuating after it has been replaced. Upon inspection discovered that thermal expansion tank had failed causing T&P to blow. Replaced for homeowner as well as flushed water heater due to them. Already purchasing a repair to solve this issue. Replaced expansion tank with new successfully, tested no leaks. Cleaned up work area did not collect.
Static decline
Completed furnace maintenance and inspection. I checked all components and amp draws. I tested airflow and temp split. I cleaned up furnace and flame sensor. I found no issues with system. Talked with customer about surge protection and air purification. Customer opted to install surge protection for today on furnace and ac. Installed surge protectors and systems is running at departure.
Sold
Sold
Sold
Sold
Sold 1 star
Upon arrival I began the furnace tune up. First, I did a static pressure test on the system. The manufacturer has this system rated for a max static pressure of .5 and when testing the system it showed to be at .92 which almost double what it should be. My Field Supervisor Nick will be over tomorrow morning at 930am to find out why the static is so high. I then continued by checking all the electrical components which were testing within specifications. I put a new filter in the system with a size 20x25x4inch filter. There was no filter in the system at arrival today but the blower wheel was still very clean today. I cleaned your flame sensor and made sure everything was heating properly besides the static pressure. If you have any questions or concerns please call us. Have a great week and weekend ahead! P.S. I took payment via CC in the amount of $75.00 for the new filter today.