Grain Valley, MO Residential HVAC & Plumbing Services
LBA Heating, Cooling, Plumbing & Electrical was started by people just like you who want and insist on high quality and reliable service. In Grain Valley, MO and throughout the Kansas City area, we treat each family and home as if it were our own. That includes rising to the challenge of being a Hero any time the need calls for extraordinary measures.
From routine maintenance to 24/7 emergency repairs, LBA Heating, Cooling, Plumbing & Electrical has you covered for all your home plumbing, heating, and air conditioning needs. The same goes for new and replacement system installations. Read our reviews and find out why your neighbors consider us to be their nearby heating and air company and local plumber in Grain Valley, MO.
Recent Jobs and Reviews in Grain Valley, MO
Grain Valley, MO at a glance
LBA Air Conditioning, Heating & Plumbing has completed 25 jobs in Grain Valley, MO between September 2024 and October 2024.
The most recent job was on October 11, 2024.
LBA Air Conditioning, Heating & Plumbing has completed 28 jobs in Grain Valley, MO in the last 12 months. The first job there was in March 2015.
Our Local Reviews by City
- Adrian, MO (2)
- Avondale, MO (1)
- Basehor, KS (24)
- Bates City, MO (1)
- Belton, MO (33)
- Blue Springs, MO (72)
- Bonner Springs, KS (30)
- Buckner, MO (1)
- Bucyrus, KS (6)
- Columbia, MO (1)
- De Soto, KS (25)
- Dearborn, MO (1)
- Edwardsville, KS (14)
- Eudora, KS (9)
- Fairway, KS (93)
- Freeman, MO (1)
- Gardner, KS (14)
- Gladstone, MO (65)
- Grain Valley, MO (58)
- Grandview, MO (75)
- Greenwood, MO (3)
- Holt, MO (3)
- Houston Lake, MO (7)
- Independence, MO (184)
- Kansas City, KS (427)
- Kansas City, MO (2902)
- Kearney, MO (3)
- Lake Lotawana, MO (4)
- Lake Quivira, KS (22)
- Lake Waukomis, MO (4)
- Lake Winnebago, MO (1)
- Lansing, KS (2)
- Lawrence, KS (19)
- Leavenworth, KS (8)
- Leawood, KS (429)
- Lee's Summit, MO (164)
- Lenexa, KS (608)
- Liberty, MO (116)
- Lone Jack, MO (1)
- Louisburg, KS (5)
- Merriam, KS (21)
- Mission, KS (204)
- Mission Hills, KS (78)
- North Kansas City, MO (10)
- Northmoor, MO (1)
- Oak Grove, MO (13)
- Odessa, MO (1)
- Olathe, KS (632)
- Ottawa, KS (1)
- Overland Park, KS (1458)
- Paola, KS (1)
- Parkville, MO (191)
- Peculiar, MO (1)
- Platte City, MO (13)
- Pleasant Hill, MO (1)
- Pleasant Valley, MO (4)
- Prairie Village, KS (527)
- Prairie Village New, KS (2)
- Raymore, MO (27)
- Raytown, MO (84)
- Riverside, MO (18)
- Roeland Park, KS (189)
- Shawnee, KS (1045)
- Shawnee Mission, KS (2)
- Smithville, MO (1)
- Spring Hill, KS (13)
- Stilwell, KS (66)
- Sugar Creek, MO (7)
- Weatherby Lake, MO (31)
- Wellsville, KS (1)
- Westwood, KS (30)
- Westwood Hills, KS (18)
Job Locations and Reviews
Static decline
Happy Call
Went for a furnace maintenance today. Started off with a static pressure test, it passed. I changed the filter for the furnace and the humidifier, due to the old ones being dirty. Did a carbon monoxide leak test, there was no leaks. Gas pressure met factory specifications. Pressure switch passed. Blower wheel was slightly dirty, but the blower motor amperage passed. The exhaust flue was in great condition. Did a combustion analysis test, it passed. temperature split between the supply and return duct passed. Unit was up and running upon departure. Thank you for choosing LBA services!
Completed furnace inspections on both systems. Main system was found to have a failing inducer, rotten flue pipe, gas line connection that was against code. Repaired said items and furnace is performing at optimum efficiency now. AC on main system had failed capacitor, replaced and system is now operational. Checked refrigerant pressures and they were within specifications. Second system for addition tested within manufacturer specifications and no recommendations. Both systems operating normally upon departure.
X
Conducted maintenance on both furnaces.
.
.
.
.
Static decline
Completed furnace inspection for customer. All aspects of system tested within manufacturer specifications aside from static pressure which was failing. Contacted field supervisor for further assessment. System operating normally upon departure.
Came to assess system for repair needs.
A
A
A
A
We will be holding off on this job. Possibly doing it in the future maybe sometime next year. Fixing the static pressure and the airflow issues isn’t very ideal in the systems, life and performance. We want to get this fixed as soon as possible. In the future, we will try to honor the same price we currently have however, this is not a guarantee.
Na
Na
Na
Na
With a high static, we need to add a second return with two return vents. We will pull air from a utility closet in the basement and we will push air to relieve pressure into the garage. We will takeoff the UV light that is currently on the throat of the furnace and we will upgrade it and install a brand new one. Two discounts have been added one for military and another for fast install. I will talk to Matt and try to get a better discount. We will also try to get this work done and as little time as possible. No more than half a day. I will call Carol Monday, 1 October 2. See where we’re sitting. We can’t have this furnace. Running with a static the way it is. It’s putting way too much pressure on the system. A ton of strain on the heat exchanger, and the motor is over amp in and running in high speed. We will most likely have motor issues as well as heat. Exchanger issues very soon if it’s not fixed. Because the static pressure is so high the board is also tripping the high static s
Upon arrival I began the furnace tune up. First, I did a static pressure test. Your system is rated for a maximum of .5 and the system is testing at 1.26 which is currently failing and putting too much pressure on the system. The failed static is also causing the blower motor to overamp which is something we must get taken care of. I checked all the electrical components and they were within specs except for the blower motor, of course. The blower wheel itself looks good and clean today. I checked for Carbon Monoxide and found Zero PPM(parts per million). My Field Supervisor Walker will be over soon to find a solution to the high static and high blower motor running amps. If you have any questions or concerns please call us! Have a great weekend!
Upon arrival I began my furnace tune up. First, I did a static pressure test. The system is rated for a max of .5 and your system is testing at .76 currently which is failing. Meaning it’s putting too much stress in the furnace. We have a Field Supervisor coming out next week on Tuesday at 9am to find a solution for the high static pressure. I checked all the electrical components which were within specs, cleaned the flame sensor. Checked the igniter me it’s working properly. Temperature split was at 53 degree which is also within specifications. The system is running well except for the static pressure being way too high. We want to get this fixed because if we leave it the way it is now, it won’t last the full amount of time it should last. High static takes years off the life of a system. Just wanted to make sure you guys know how important it is that we get this looked at and fixed I hope. If you have any questions or concerns please call us! Have a great weekend ahead!