Grain Valley, MO Residential HVAC & Plumbing Services
LBA Heating, Cooling, Plumbing & Electrical was started by people just like you who want and insist on high quality and reliable service. In Grain Valley, MO and throughout the Kansas City area, we treat each family and home as if it were our own. That includes rising to the challenge of being a Hero any time the need calls for extraordinary measures.
From routine maintenance to 24/7 emergency repairs, LBA Heating, Cooling, Plumbing & Electrical has you covered for all your home plumbing, heating, and air conditioning needs. The same goes for new and replacement system installations. Read our reviews and find out why your neighbors consider us to be their nearby heating and air company and local plumber in Grain Valley, MO.
Recent Jobs and Reviews in Grain Valley, MO
Grain Valley, MO at a glance
LBA Air Conditioning, Heating & Plumbing has completed 25 jobs in Grain Valley, MO between December 2024 and January 2025.
The most recent job was on January 3, 2025.
LBA Air Conditioning, Heating & Plumbing has completed 28 jobs in Grain Valley, MO in the last 12 months. The first job there was in March 2015.
Our Local Reviews by City
- Adrian, MO (2)
- Avondale, MO (1)
- Basehor, KS (24)
- Bates City, MO (1)
- Belton, MO (33)
- Blue Springs, MO (72)
- Bonner Springs, KS (30)
- Buckner, MO (1)
- Bucyrus, KS (6)
- Columbia, MO (1)
- De Soto, KS (25)
- Dearborn, MO (1)
- Edwardsville, KS (14)
- Eudora, KS (9)
- Fairway, KS (93)
- Freeman, MO (1)
- Gardner, KS (14)
- Gladstone, MO (65)
- Grain Valley, MO (58)
- Grandview, MO (75)
- Greenwood, MO (3)
- Holt, MO (3)
- Houston Lake, MO (7)
- Independence, MO (184)
- Kansas City, KS (427)
- Kansas City, MO (2902)
- Kearney, MO (3)
- Lake Lotawana, MO (4)
- Lake Quivira, KS (22)
- Lake Waukomis, MO (4)
- Lake Winnebago, MO (1)
- Lansing, KS (2)
- Lawrence, KS (19)
- Leavenworth, KS (8)
- Leawood, KS (429)
- Lee's Summit, MO (164)
- Lenexa, KS (608)
- Liberty, MO (116)
- Lone Jack, MO (1)
- Louisburg, KS (5)
- Merriam, KS (21)
- Mission, KS (204)
- Mission Hills, KS (78)
- North Kansas City, MO (10)
- Northmoor, MO (1)
- Oak Grove, MO (13)
- Odessa, MO (1)
- Olathe, KS (632)
- Ottawa, KS (1)
- Overland Park, KS (1458)
- Paola, KS (1)
- Parkville, MO (191)
- Peculiar, MO (1)
- Platte City, MO (13)
- Pleasant Hill, MO (1)
- Pleasant Valley, MO (4)
- Prairie Village, KS (527)
- Prairie Village New, KS (2)
- Raymore, MO (27)
- Raytown, MO (84)
- Riverside, MO (18)
- Roeland Park, KS (189)
- Shawnee, KS (1045)
- Shawnee Mission, KS (2)
- Smithville, MO (1)
- Spring Hill, KS (13)
- Stilwell, KS (66)
- Sugar Creek, MO (7)
- Weatherby Lake, MO (31)
- Wellsville, KS (1)
- Westwood, KS (30)
- Westwood Hills, KS (18)
Job Locations and Reviews
Upon arrival I began the furnace tune up. First, I ran a static pressure test. This system is rated for a maximum static pressure of .5 and your system is testing at .86 which is failing currently. Next, I ran a Carbon Monoxide test on the supply air in the system and I got a hit of 190ppm at a maximum. This is very unsafe. The high static has caused the heat exchanger too much stress by running harder than the manufacturer created it to do. This has caused the HX to crack and leak carbon monoxide. Per the EPA Rules & Regulations I am required by law to shut the unit down because it is not safe to operate. We are also required to add a “Red Tag” to the unit which Jamie will have you sign. The stress was also causing the inducer motor to overamp which can cause damage in the future. If you have any questions or concerns please feel free to call us! Your LBA Technician, Tyler Rickard P.S. No payment will be due for todays visit. Once we get the new furnace or new heat exchanger in and ba
No answer
Installed new Full System Furnace Model GR9S800803BN, AC Model GLXS3BN3610, Evap Coil Model CAPTA3626B3 2 Year Labor Warranty 10 Year Parts Warranty Limited Lifetime Heat Exchanger Warranty
Customer wasn’t available
Sold full system and 1 star
Upon arrival the system would light and gas released but it wouldn’t stay lit for more than a few seconds. I removed the flame sensor and cleaned it, then reinstalled it and tested the unit again and it fired up and stayed lit. That issue is resolved. Next, I ran a static pressure test. Your unit is rated for a maximum static pressure of .5 and your system is testing off my chart, which is failing. I believe the return side of the system is struggling to pull air into the system. My Field Supervisor Nick will discuss this in further detail with you. Next, I ran a CO test and got a hit at 32ppm(parts per million). Any amount of CO is dangerous and per the EPA rules and regulations we are required by law the shut the furnace down as it is currently unsafe to operate due to a failed heat exchanger. Nick will find some solutions to these issues for you. If you have any questions or concerns please feel free to call us! Your LBA Technician, Tyler Rickard P.S. I took payment today in the amo
Went for a maintenance call today. Tested for static pressure system was passing downstairs. Upstairs unit is failing customer is aware. Did a co reading downstairs no co was detected. Did a get a co reading for upstairs did verify with supervisor but no cracks were detected. Used another meter that read zero carbon monoxide. Temp split passes for both system. Did replace filter for both units. All electrical components are passing. Both blower wheels are dirty and do need a cleaning. Did mention ductwork needs to be improved with customer. Supervisor will have solutions for customer. No further wear and tear. Thank you for choosing LBA services-Johann.
Decline
Completed heating inspection for customer. All aspects of system tested within manufacturer specifications. No recommendations at this time.
Nn
Nn
Nn
Nn
Filter installed
Went for a maintenance call today. Tested for static pressure system is passing. Did a co test no co was detected when testing. Inspected heat exchanger no wear and tear. All electrical components are passing for system. Did replace filter for customer. System is up and running before leaving. Thank you for choosing LBA services-Johann.
N
N
N
N
Went for a maintenance call today. Tested for static pressure, system passing. Did replace filter for customer. Did a co test and no co was detected when testing. Inspected heat exchanger no wears and tear. Temp split is passing for system. All electrical components are passing for system. No wear and tear. Thank you for choosing LBA services-Johann.
Contacted management for filter situation. Found low volt shorts causing fuse to blow. Fixed that and all ops are okay at departure.
Customer recognized me and was not having any of it as I was just out here less than a year ago , 5 times in the past 2 years and never explained static so she didn’t understand why just now I’m saying something
Went for a furnace inspection today. Did a static pressure test, it failed. Did a carbon monoxide and gas leak check, no leaks. Combustion analysis test passed. Inducer motor amperage failed, it is over amping. Temperature split between the supply and return duct passed. Blower motor amperage passed and blower wheel is clean. Exhaust flu is in good condition. Duct work is dirty as well. Thank you for choosing LBA services!
Went for a maintenance call today. Tested for static pressure, system is passing on static. Did a co test, no co was detected when testing. Inspected heat exchanger no wear and tear. Did a temp split and is passing. All electrical components are passing for system. No further wear and tear. Thank you for choosing LBA services-Johann.
Arrived for furnace maintenance on air handler. Static pressure is passing. Heat strips look good. Blower wheel is clean. There’s a good temperature split between the return and supply air. All electrical components are running properly at this time. I changed the furnace filter today. System is running upon departure. Thanks for choosing LBA.